CHAPTER 37. SOLAR ENERGY EQUIPMENT

Solar energy use is becoming more economical as the cost of energy continues to climb, especially with increasing government and utility incentives as well as growing interest in green and/or sustainable construction. In addition, many countries consider solar and renewable energy as a security measure to ensure the availability of power under adverse conditions. While the United States continues to grow its solar industry, China, Europe, Asia, and the Mediterranean basin are leading development of advanced manufacturing techniques and applications. However, equipment and systems are still very similar in all markets; therefore, this chapter primarily discusses the basic equipment used, with particular attention to collectors. More detailed descriptions of systems and designs can be found in Chapter 35 of the 2019 ASHRAE Handbook— HVAC Applications.

Commercial and industrial thermal solar energy systems are generally classified according to the heat transfer medium used in the collector loop (i.e., air or liquid). Although both systems share basic fundamentals of conversion of solar radiant energy, the equipment used in each is entirely different. Air systems are primarily limited to forced-air space heating and industrial and agricultural drying processes. Liquid systems are suitable for a broader range of applications, such as hydronic space heating, service water heating, industrial process water heating, energizing heat-driven air conditioning, and pool heating, and as a heat source for series-coupled heat pumps. Because of this wide range in capability, liquid systems are more common than air systems in commercial and industrial applications.

As shown in Table 1, global installed thermal capacity of solar collectors at the end of 2012 reached 269.3 gigawatts (GWth) (Weiss and Mauthner 2014). Unglazed plastic collectors are used mainly for low-temperature (e.g., swimming pool) water heating; their main markets are in North America (i.e., the United States and Canada) with an installed capacity of 14.8 GWth, followed by Australia (3.0 GWth). Glazed flat-plate and evacuated-tube collectors, which are mainly used to generate domestic hot water and space heating, dominate the market in China (180.4 GWth), Germany (11.4 GWth), Turkey (10.8 GWth), India (4.5 GWth), and Brazil (4.2 GWth).

According to the European Solar Thermal Industry (ESTIF 2014), at the end of 2013 the total thermal capacity in operation in the EU exceeded 30 GWth, corresponding to 464 million ft2 43.1 million m2 of glazed collector area. Germany is the leader in terms of market volume, with about 38% of the European market, whereas Austria, Greece, Italy, Spain, France, and Poland together account for about 43%. In terms of solar thermal capacity in operation per capita, the European average is at 58.8 kWth/1000 capita. Cyprus, where more than 90% of all buildings are equipped with solar collectors, leads Europe with 565 kWth/1000 capita, followed by Austria at 346 kWth/1000 capita, and Greece at about 264 kWth/1000 capita. Solar hot-water systems are now mandatory in new buildings according to solar ordinances in Cyprus, Greece, Italy, Portugal, Slovenia, Spain, and elsewhere in Europe.

Table 1. Worldwide Solar Capacity by Type

 

Capacity, GWth

Equiv. Glazed Collector Area, 1,000,000 ft2

Glazed flat-plate collectors

71.0

1092

Evacuated-tube collectors

174.0

2677

Unglazed plastic collectors

22.7

349

Glazed and unglazed air collectors

1.6

24

  Total

269.3

4142


China remains the leader in the global solar heating industry, producing an estimated 50.1 GWth or 771 million ft2 of collectors in 2013 (REN21 2014). Practically all installations in China use evacuated-tube collectors for domestic hot water only. The trend in Europe is towards larger solar-combi systems that provide both domestic hot water and space heating, accounting for half of the annual market in Austria and Germany (Balaras et al. 2010), as well as multipurpose heat-pump-assisted solar systems (Todorovic et al. 2010). The U.S. market for solar hot-water collectors (excluding unglazed swimming pool heating) is still relatively small but is gaining ground (especially in California): some states have set solar thermal carve-outs in their renewable portfolio standards (RPS), or allow electric utilities to meet RPS requirements with solar water heating systems (REN21 2014). Over a six-year period, Brazil’s market more than doubled, with nearly 1 GWth added in 2013 for a total approaching 7 GWth. India and Japan are the largest Asian markets outside of China. In the Middle East, Israel leads for total capacity (with about 85% of households using solar water heaters), followed by Jordan and Lebanon. The most mature markets in Africa include Egypt, Mozambique, Tunisia, Zimbabwe, and South Africa, although markets in many developing countries are challenged by a lack of standards, leading to use of inferior products and poor installations, which have undermined the systems’ reputation.

Photovoltaic (PV) systems convert light from the sun directly into electricity for a wide variety of applications. The cost of PV systems has dropped dramatically in the U.S. over the past few years, from about $6-$8 per watt installed in 2009 to $3-$4 in 2014, and is expected to continue to drop (Feldman et al. 2014). This cost reduction has made PV systems considerably more economical, particularly when combined with federal tax credits and local incentives, and the amount of installed capacity has therefore increased dramatically over the years.

In 2013, the global cumulative installed photovoltaic capacity reached 139 GWp and was capable of producing at least 160 TWh annually (EPIA 2014). This was the first year that solar PV capacity exceeded wind capacity worldwide. Europe remains the world’s leader in terms of cumulative installed capacity (about 82 GWp at the end of 2013), dominated by Germany (447 Wp per capita), Italy (295 Wp per capita), Belgium (267 Wp per capita), and Greece (234 Wp per capita). However, in most countries, PV remains a policy-driven market. Other regions are also growing quickly, with 41 GWp in Asian Pacific countries and 14 GWp in the Americas. Among the leading countries, China was the top market in 2013 with a new installed capacity of 11.8 GWp, followed by Europe (9.9 GWp); Japan (6.9 GWp); the United States (4.8 GWp); India (1.1 GWp); and Korea, Thailand, and Canada (about 0.4 GWp each). After four consecutive quarters of installing more than 1 GWp, driven primarily by the utility solar PV market, cumulative operating PV capacity in the United States exceeds 16 GWp (SEIA 2014).

1. SOLAR HEATING SYSTEMS

Solar energy system design requires careful attention to detail because solar radiation is a low-intensity form of energy, and the equipment to collect and use it can be expensive. A brief overview of air and liquid systems is presented here to show how the equipment fits into each type of system. Chapter 35 of the 2019 ASHRAE Handbook—HVAC Applications covers solar energy use, and books on design, installation, operation, and maintenance are also available (ASHRAE 1988, 1990, 1991).

Solar energy and HVAC systems often use the same components and equipment. This chapter covers only the following elements, which are either exclusive to or have specific uses in solar energy applications:

  • Collectors and collector arrays

  • Thermal energy storage

  • Heat exchangers

  • Controls

Thermal energy storage is also covered in Chapter 51, heat exchangers are also covered in Chapter 48, as well as pumps in Chapter 44, and fans in Chapter 21.

1.1 AIR-HEATING SYSTEMS

Air-heating systems circulate air through ducts to and from an air heating collector (Figure 1). Air systems are effective for space heating because a heat exchanger is not required and the collector inlet temperature is low throughout the day (approximately room temperature). Air systems do not need protection from freezing, overheat, or corrosion. Furthermore, air costs nothing and does not cause disposal problems or structural damage. However, air ducts and air-handling equipment require more space than pipes and pumps, ductwork is hard to seal, and leaks are difficult to detect. Fans consume more power than the pumps of a liquid system, but if the unit is installed in a facility that uses air distribution, only a slight power cost is chargeable against the solar space-heating system. Thermal storage for hot-air systems has been problematic as well because of the difficulty in controlling humidity and mold growth in pebble beds and other such devices, particularly in humid climates.

Air-Heating Space and Domestic Water Heater System

Figure 1. Air-Heating Space and Domestic Water Heater System


Most air space-heating systems also preheat domestic hot water through an air-to-liquid heat exchanger. In this case, tightly fitting dampers are required to prevent reverse thermosiphoning at night, which could freeze water in the heat exchanger coil. If this system heats only water in the summer, the parasitic power consumption must be charged against the solar energy system because no space heating is involved and there are no comparable energy costs associated with conventional water heating. In some situations, solar water-heating systems could be more expensive than conventional water heaters, particularly if electrical energy costs are high. To reduce parasitic power consumption, some systems use the low speed of a two-speed fan.

1.2 LIQUID- HEATING SYSTEMS

Liquid-heating systems circulate a liquid, often a water-based fluid, through a solar collector (Figures 2 and 3). The liquid in solar collectors must be protected against freezing, which could damage the system.

Simplified Schematic of Indirect Nonfreezing System

Figure 2. Simplified Schematic of Indirect Nonfreezing System


Freezing is the principal cause of liquid system failure. For this reason, freeze tolerance is an important factor in selecting the heat transfer fluid and equipment in the collector loop. A solar collector radiates heat to the cold sky and freezes at air temperatures well above 32°F. Where freezing conditions are rare, small solar heating systems are often equipped with low-cost protection devices that depend on simple manual, electrical, and/or mechanical components (e.g., electronic controllers and automatic valves) for freeze protection. Because of the large investment associated with most commercial and industrial installations, solar designers and installers must consider designs providing reliable freeze protection, even in the warmest climates.

Simplified Schematic of Indirect Drainback Freeze Protection System

Figure 3. Simplified Schematic of Indirect Drainback Freeze Protection System


Thermosiphon solar domestic hot-water heating systems operate at low, self-regulated collector flow rates. Their performance is generally better in temperate climates than active (using a pump to circulate the fluid) systems operating at conventional flow rates and is comparable to pump systems operating at low collector flow rates. Thermosiphon systems dominate the market in residential and low-rise building applications in southern Europe and China, and Australia. The collector fluid is circulated by natural convection, eliminating the need for the pump and controller of an active system. The hot-water storage tank is placed above the collector area. The flow rate varies depending on the absorbed solar radiation, fluid temperatures, system geometry, etc.

 Direct and Indirect Systems

In a direct liquid system, city water circulates through the collector. In an indirect system, the collector loop is separated from the high-pressure city water supply by a heat exchanger. In areas of poor water quality, isolation protects the collectors from fouling by minerals in the water. Indirect systems also offer greater freeze protection, so they are used almost exclusively in commercial and industrial applications.

 Freeze Protection

Direct systems, used where freezing is infrequent and not severe, can avoid freeze damage by (1) recirculating warm storage water through the collectors, (2) continually flushing the collectors with cold water, or (3) isolating collectors from the water and draining them. Systems that can be drained to avoid freeze damage are called draindown systems. Although all of these methods can be effective, none of them are generally approved by sanctioning bodies or recommended by manufacturers. Use caution when designing direct systems in freezing climates with any of these freeze protection schemes.

Indirect systems use two methods of freeze protection: (1) nonfreezing fluids and (2) drainback.

 Nonfreezing Fluid Freeze Protection.
 The most popular solar energy system for commercial use is the indirect system with a nonfreezing heat transfer fluid to transmit heat from the solar collectors to storage (Figure 2). The most common heat transfer fluid is water/propylene glycol, although other heat transfer fluids such as silicone oils, hydrocarbon oils, or refrigerants can be used. Because the collector loop is closed and sealed, the only contribution to pump pressure is friction loss; therefore, the location of solar collectors relative to the heat exchanger and storage tank is not critical. Traditional hydronic sizing methods can be used for selecting pumps, expansion tanks, heat exchangers, and air removal devices, as long as the heat transfer liquid’s thermal properties are considered.

When the control system senses an increase in solar panel temperature, the pump circulates the heat transfer liquid, and energy is collected. The same control also activates a pump on the domestic water side that circulates water through the heat exchanger, where it is heated by the heat transfer fluid. This mode continues until the temperature differential between the collector and the tank is too slight for meaningful energy to be collected. At this point, the control system shuts the pumps off. At low temperatures, the nonfreezing fluid protects the solar collectors and related piping from bursting. Because the heat transfer fluid can affect system performance, reliability, and maintenance requirements, fluid selection should be carefully considered.

Because the collector loop of the nonfreezing system remains filled with fluid, it allows flexibility in routing pipes and locating components. However, a double-separation (double-wall) heat exchanger is generally required (by local building codes) to prevent contamination of domestic water in the event of a leak. The double-wall heat exchanger also protects the collectors from freeze damage if water leaks into the collector loop. However, the double-wall heat exchanger reduces efficiency by forcing the collector to operate at a higher temperature. The heat exchanger can be placed inside the tank, or an external heat exchanger can be used, as shown in Figure 2. The collector loop is closed and, therefore, requires an expansion tank and pressure-relief valve. Air purge is also necessary to expel air during filling and to remove air that has been absorbed into the heat transfer fluid.

Overtemperature protection is necessary to ensure that the system operates within safe limits and to prevent collector fluid from corroding the absorber or heat exchanger. For maximum reliability, glycol should be replaced every few years.

In some cases, systems have failed because the collector fluid in the loop thermosiphoned and froze the water in the heat exchanger. This disastrous situation must be avoided by design if the water side is exposed to the city water system because the collector loop eventually fills with water, and all freeze protection is lost.

 Drainback Freeze Protection.
 A drainback solar water-heating system (see Figure 3) uses ordinary water as the heat transport medium between the collectors and thermal energy storage. Reverse-draining (or back-siphoning) the water into a drainback tank located in a nonfreezing environment protects the system from freezing whenever the controls turn off the circulator pump or a power outage occurs.

For drainback systems with a large amount of working fluid in the collector loop, heat loss can be significantly decreased and overall efficiency increased by including a tank for storing the heat transfer fluid at night. Using a night storage tank in large systems is an appropriate strategy even for regions with favorable meteorological conditions.

The drainback tank can be a sump with a volume slightly greater than the collector loop, or it can be the thermal energy storage tank. The collector loop may or may not be vented to the atmosphere. Many designers prefer the nonvented drainback loop because makeup water is not required and the corrosive effects of air that would otherwise be ingested into the collector loop are eliminated.

The drainback system is virtually fail-safe because it automatically reverts to a safe condition whenever the circulator pump stops. Furthermore, a 20 to 30% glycol solution can be added to drainback loops for added freeze protection in case of controller or sensor failure. Because the glycol is not exposed to stagnation temperatures, it does not decompose.

A drainback system requires space for the necessary pitching of collectors and pipes for proper drainage. Also, a nearby heated area must have a room for the pumps and the drainback tank. Plumbing exposed to freezing conditions drains to the drainback tank, making the drainback design unsuitable for sites where the collector cannot be elevated above the storage tank.

Both dynamic and static pressure losses must be considered in drainback system design. Dynamic pressure loss is due to friction in the pipes, and static pressure loss is associated with the distance the water must be lifted above the level of the drainback tank to the top of the collector. There are two distinct designs of drainback systems: the oversized downcomer (or open-drop) and the siphon return. The static head requirement remains constant in the open-drop system and decreases in the siphon return.

Drainback performs better than other systems in areas with low temperatures or high irradiance. Drainback has the advantage that time and energy are not lost in reheating a fluid mass left in the collector and associated piping (as in the case of antifreeze systems). Also, water has a higher heat transfer capacity and is less viscous than other heat transfer fluids, resulting in smaller parasitic energy use and higher overall system efficiency. In closed-return (indirect) designs, there is also less parasitic energy consumption for pumping because water is the heat transfer fluid. Drainback systems can be worked on safely under stagnation conditions, but should not be restarted during peak solar conditions to avoid unnecessary thermal stress on the collector.

1.3 SOLAR THERMAL ENERGY COLLECTORS

 Collector Types

Solar collectors depend on air heating, liquid heating, or liquid-vapor phase change to transfer heat. The most common type for commercial, residential, and low-temperature (<200°F) industrial applications is the flat-plate collector.

 Liquid-Heating Collectors.
 Figure 4A shows a cross section of a flat-plate liquid collector. A flat-plate collector contains an absorber plate covered with a black coating and one or more transparent covers. The covers are transparent to incoming solar radiation and relatively opaque to outgoing (long-wave) radiation, but their principal purpose is to reduce convection heat loss. The collector box is insulated to prevent conduction heat loss from the back and edge of the absorber plate. This type of collector can supply hot water or air at temperatures up to 200°F, although efficiency diminishes rapidly above 160°F. The advantages of flat-plate collectors are simple construction, low relative cost, no moving parts, relative ease of repair, and durability. They also absorb diffuse radiation, which is a distinct advantage in cloudy climates.

Another type of collector is the integral collector storage (ICS) system. These collectors incorporate thermal storage within the collector itself. The storage tank surface serves as the absorber surface. Most ICS systems use only one tank, but some use several tanks in series. As with flat-plate collectors, insulated boxes enclose the tanks with transparent coverings on the side facing the sun. Although the simplicity of ICS systems is attractive, they are generally suitable only for applications in mild climates with small thermal storage requirements. Freeze protection by manually draining the unit is necessary in colder climates.

 

Solar Flat-Plate Collectors

Figure 4. Solar Flat-Plate Collectors


Still another type of collector is the evacuated tube, where the absorber mechanism is encased in a glass vacuum tube (Figure 5). Absorbers may be a simple copper fin tube on a copper sheet, a large copper cylinder in ICS applications, or a heat pipe. The latter uses a phase-change fluid to transfer heat to a common manifold where the working fluid circulates. The vacuum envelope reduces convection and conduction losses, so the tubes can operate at higher temperatures than flat-plate collectors. Like flat-plate collectors, they collect both direct and diffuse radiation. Because of its high-temperature capability, the evacuated-tube collector is favored for energizing heat-driven air-conditioning equipment, particularly when combined with concentrating reflectors behind the tubes.

Flat-plate and evacuated-tube collectors are usually mounted in a fixed position. Concentrating collectors are available that must be arranged to track the movement of the sun. These are mainly used for high-temperature industrial applications above 240°F. For more information on concentrating collectors, see Chapter 35 of the 2019 ASHRAE Handbook—HVAC Applications.

 

Evacuated-Tube Collector

 

Figure 5. Evacuated-Tube Collector


Finally, unglazed flat-plate absorbers are often used for low-temperature applications such as pool water heating. The most popular configurations are made of plastic structured to create an almost fully wetted surface or uses very small fins on extruded tubes. Metal absorber plates from glazed collectors are also used, but generally with a heat exchanger to avoid contact with the pool water chemicals.

 Air-Heating Collectors.
 Air-heating collectors are also contained in a box, covered with one or more glazings, and insulated on the sides and back. Figure 4B shows a cross section of a flat-plate air collector. The primary differences from liquid-heating collectors are in the design of the absorber plate and flow passages. Because the working fluid (air) has poor heat transfer characteristics, it flows over the entire absorber plate, and sometimes on both the front and back of the plate, to make use of a larger heat transfer surface. In spite of the larger surface area, air collectors generally have poorer overall heat transfer than liquid collectors. However, they are usually operated at a lower temperature for space heating applications because they require no intervening heat exchangers.

Transpired air collectors can be attached to the roof or side of a building to create a plenum for the preheated air. The collector is simply the siding material with many small holes through which the air is drawn, thus warming the air for space-heating or drying applications.

 Liquid-Vapor Collectors.
 A third class of collectors uses liquid-vapor phase change to transfer heat at high efficiency. These collectors feature a heat pipe (a highly efficient thermal conductor) placed inside a vacuum-sealed tube (Figure 5B). The heat pipe contains a small amount of fluid (e.g., methanol) that undergoes an evaporating/condensing cycle. In this cycle, solar heat evaporates the liquid, and the vapor travels to a heat sink region, where it condenses and releases its latent heat. This process is repeated by a return feed of the condensed fluid back to the solar absorber.

Most phase-change fluids have low freezing temperatures, so the heat pipe offers inherent protection to the tubes from freezing and overheating, but not to the fluid being heated. This self-limiting temperature control is a unique feature of the evacuated heat pipe collector.

 Collector Construction

 Absorber Plates.
 The key component of a flat-plate collector is the absorber plate. It contains the heat transfer fluid and serves as a heat exchanger by converting radiant energy into thermal energy. It must maintain structural integrity at temperatures ranging from below freezing to well above 300°F. Chapter 35 of the 2019 ASHRAE Handbook—HVAC Applications illustrates typical liquid collectors and shows the wide variety of absorber plate designs in use.

Materials for absorber plates and tubes are usually highly conductive metals such as copper, aluminum, and steel, although low-temperature collectors for swimming pools are usually made from extruded elastomeric material such as ethylene-propylene terpolymer (EPDM) and polypropylene. Flow passages and fins are usually copper, but aluminum fins are sometimes inductively welded to copper tubing. Occasionally, fins are mechanically attached, but there is potential for corrosion with this design. A few manufacturers produce all-aluminum collectors, but they must be checked carefully to determine whether they incorporate corrosion protection in the collector loop.

Plan View of Liquid Collector Absorber Plates

Figure 6. Plan View of Liquid Collector Absorber Plates


Figure 6 shows a plan view of typical absorber plates. The serpentine design (Figure 6A) is used less frequently because it is difficult to drain and imposes a high pressure drop, but it can produce higher temperatures at lower flow rates. Most manufacturers use absorber plates similar to those shown in Figures 6D and 6E.

In liquid collectors, manifold selection is important because the design can restrict the array piping configuration. The manifold must be drainable and free-floating, with generous allowance for thermal expansion. Some manufacturers provide a choice of manifold connections to give designers flexibility in designing arrays.

In air collectors, most manufacturers increase the heat transfer area by using fins, matrices, or corrugated surfaces (Figure 7). Many of these designs increase air turbulence, which improves collector efficiency (at the expense of increased fan power).

Figure 7 also shows cross sections of typical solar water collectors. Water passages can be integrated with the absorber plate to ensure good thermal contact (Figure 7E), or they can be soldered, brazed, or otherwise fastened to the absorber plate (Figure 7F). Manufactured collectors are made in modular sizes, typically 4 by 8 ft, and these are connected to form a bank or row. Because most commercial-scale systems involve more than 1000 ft2 of collector, there can be numerous piping connections, depending on design.

Cross Sections of Various Solar Air and Water Heater

Figure 7. Cross Sections of Various Solar Air and Water Heater


Absorber plates may be coated with spectrally selective or nonselective materials. Selective coatings are more efficient, but cost more than nonselective, or flat black, coatings. However, their higher efficiencies may reduce the overall size of the array, resulting in lower total cost. The Argonne National Laboratory has detailed guidelines on various coating materials used in solar applications (ANL 1981).

Solar collectors with colored absorbers (e.g., blue, red-brown, green) may be aesthetically attractive for building integration. Although colored collectors have lower efficiency than the typical black collectors, the difference in energy output depends on the absorber darkness. For a medium value of the coefficient of absorptance (α = 0.85), the drop in amount of energy from colored collectors (about 7 to 18%, depending on location) is satisfactory compared to the performance of collectors with black absorbers (α = 0.95). Colored collectors require a proportionately larger collector aperture area to have the same energy output as that of typical black collectors (Kalogirou et al. 2005). Selective colored absorbers are efficient in a wider range of operating temperatures than absorbers with high-emissivity paints, and selective absorbers stable to weather conditions are needed for unglazed collectors to avoid degradation by environmental effects.

 Housing.
 The collector housing is the container that provides structural integrity for the collector assembly. The housing must be structurally sound, weathertight, fire resistant, and mechanically connectable to a substructure to form an array. Collector housing materials include the following:
  • Galvanized or painted steel

  • Aluminum folded sheet stock or extruded wall materials

  • Various plastics, either molded or extruded

  • Composite wood products

  • Standard elements of the building

Extruded anodized aluminum, including extruded channels, offers durability and ease of fabrication. Grooves are sometimes included in the extruded channels to accommodate proprietary mounting fixtures. The high temperatures of a solar collector deteriorate wood housings; consequently, wood is often forbidden by fire codes.

 Glazing.
 Solar collectors for domestic hot water are usually single-glazed to reduce absorber plate convective and radiative losses. Some collectors have double glazing to further reduce these losses; however, double glazing should be restricted to applications where the value of (ti – ta)/It exceeds that of domestic hot-water applications (e.g., space heating or activating absorption refrigeration); the parameters for this ratio are defined in Equations (4) and (5). Glazing materials are plastic, plastic film, or glass. Glass can absorb the long-wave thermal radiation emitted by the absorber coating, but it is not affected by ultraviolet (UV) radiation. Because of their impact tolerance, only tempered, low-iron glass covers should be considered. These covers have a solar transmission rating of 84 to 91%.

If the probability of vandalism is high, polycarbonate, which has high impact resistance, should be considered. Unfortunately, its transmittance is not as high as that of low-iron glass, and it is susceptible to long-term UV degradation.

 Insulation.
 Collector enclosures must be well insulated to minimize heat losses. Insulation adjacent to the absorber plate must withstand temperatures up to 400°F and, most importantly, must not outgas volatile products within this range. Many insulation materials designed for construction applications are not suitable for solar collectors because the binders outgas volatiles at normal collector operating temperatures.

Solar collector insulation is typically made of mineral fiber, ceramic fiber, glass foam, plastic foam, or fiberglass. Fiberglass is the least expensive insulation and is widely used in solar collectors. For high-temperature applications, rigid fiberglass board with a minimum of binder is recommended. Also, a layer of polyisocyanurate foam in collectors is often used because of its superior R-value. Because it can outgas at high temperatures, the foam must not be allowed to contact the collector plate.

Figure 8 illustrates the preferred method of combining fiberglass and foam insulations to obtain both high efficiency and durability. Note that the absorber plate should be free-floating to avoid thermal stresses. Despite attempts to make collectors watertight, moisture is always present in the interior. This moisture can physically degrade mineral wool and reduce the R-value of fiberglass, so drainage and venting are crucial.

Cross Section of Suggested Insulation to Reduce Heat Loss from Back Surface of Absorber

Figure 8. Cross Section of Suggested Insulation to Reduce Heat Loss from Back Surface of Absorber


1.4 ROW DESIGN

 Piping Configuration

Most commercial and industrial systems require a large number of collectors. Connecting the collectors with one set of manifolds makes it difficult to ensure drainability, balanced flow, and low pressure drop. An array usually includes many individual groups of collectors, called rows, to provide the necessary flow characteristics. Rows can be grouped into (1) parallel flow or (2) combined series-parallel flow. Parallel flow is the most frequently used because it is inherently balanced, has low pressure drop, and is drainable. Figure 9 illustrates various collector header designs for forming a parallel-flow row (the flow is parallel but the collectors are connected in series).

Collector Manifolding Arrangements for Parallel-Flow Row

Figure 9. Collector Manifolding Arrangements for Parallel-Flow Row


Generally, flat-plate collectors connect to the main piping in one of the methods shown in Figure 9. The external manifold collector has a small-diameter connection meant to carry only the flow for one collector. It must be connected individually to the manifold piping, which is not part of the collector panel, as depicted in Figure 9A.

Internal manifold collectors incorporate the manifold piping integral with each collector (Figure 9B). Headers at either end of the collector distribute flow to the risers. Several collectors with large headers can be placed side by side to form a continuous supply and return manifold. With 1 in. headers, four to six 40 ft2 collectors can be placed side by side. Collectors with 1 in. headers can be mounted in a row without producing unbalanced flow. Most collectors have four plumbing connections, some of which may be capped if the collector is located on the end of the array. Internally manifolded collectors have the following advantages:

  • Piping costs are lower because fewer fittings and less insulation are required.

  • Heat loss is less because less piping is exposed.

  • Installation is more attractive.

Some of their disadvantages are as follows:

  • For drainback systems, the entire row must be pitched, thus complicating mounting.

  • Flow may be imbalanced if too many collectors are connected in parallel.

  • Removing the collector for servicing may be difficult.

  • Stringent thermal expansion requirements must be met if too many collectors are combined in a row.

 Velocity Limitations

Fluid velocity limits the number of internally manifolded collectors that can be contained in a row. For 1 in. headers, up to eight 40 ft2 collectors can usually be connected for satisfactory performance. If too many are connected in parallel, the middle collectors will not receive enough flow, and performance will decrease. Connecting too many collectors also increases pressure drop. Figure 10 shows the effect of collector number on performance and pressure drop for one particular design. Newton and Gilman (1983) describe a general method to determine the number of internally manifolded collectors that can be connected.

Pressure Drop and Thermal Performance of Collectors with Internal Manifolds Numbers

Figure 10. Pressure Drop and Thermal Performance of Collectors with Internal Manifolds Numbers


Flow restrictors can be used to accommodate a large number of collectors in a row. The flow distribution in the 12 collectors of Figure 11 would not be satisfactory without the flow restrictors shown at the interconnections. The flow restrictors are barriers with a drilled hole of the diameter indicated. Some manufacturers calculate the required hole diameters and provide predrilled restrictors.

Chapter 22 of the 2017 ASHRAE Handbook—Fundamentals gives information on sizing piping. Knowles (1981) provides the following expression for the minimum acceptable header diameter:

(1)

where

D

=

header diameter, in.

N

=

number of collectors in module

Q

=

recommended flow rate for collector, gpm

Δp

=

pressure drop across collector at recommended flow rate, psi

Because pipe is available in a limited number of diameters, selection of the next larger size ensures balanced flow. Usually, the sizes of supply and return piping are graduated to maintain the same pressure drop while minimizing piping cost. Complicated configurations may require a hydraulic static regain calculation.

 Thermal Expansion

Thermal expansion will affect the row shown in Figure 11. Thermal expansion (or contraction) of a module of collectors in parallel may be estimated by the following equation:

(2)

where

Δ

=

expansion or contraction of collector array, in.

n

=

number of collectors in array

tc

=

collector temperature, °F (generally the maximum stagnation temperature)

ti

=

installation temperature of collector array, °F (generally the lowest possible air temperature)

Because absorbers are rigidly connected, the absorber must have sufficient clearance from the side frame to allow the expansion indicated in Equation (2). Information on dealing with expansion in piping may also be found in Chapter 46.

Flow Pattern in Long Collector Row with Restrictions

Figure 11. Flow Pattern in Long Collector Row with Restrictions


1.5 ARRAY DESIGN

 Piping Configuration

 Liquid Systems.
 To maintain balanced flow, an array or field of collectors should be built from identical rows configured as described in previous sections. Whenever possible, rows must be connected in reverse-return fashion (Figure 12), which ensures that the array is self-balanced. With proper care, an array can drain, which is an essential requirement for drainback freeze protection.

Piping to and from the collectors must be sloped properly in a drainback system. Typically, piping and collectors must slope to drain at 1/4 in. per linear foot. Elevations throughout the array, especially the highest and lowest point of the piping, should be noted on the drawings.

Reverse-Return Array Piping

Figure 12. Reverse-Return Array Piping


The external manifold collector has different mounting and plumbing considerations from the internal manifold collector (Figure 13). A row of externally manifolded collectors can be mounted horizontally, as shown in Figure 13A. The lower header must be pitched as shown. The pitch of the upper header can be either horizontal or pitched toward the collectors so it can drain back through the collectors.

Arrays with internal manifolds pose a greater challenge in designing and installing the collector mounting system. For these collectors to drain, the entire bank must be tilted, as shown in Figure 13B.

Reverse return always implies an extra pipe run. Sometimes, it is more convenient to use direct return (Figure 14). In this case, balancing valves are needed to ensure uniform flow through the rows. The balancing valves must be connected at the row outlet to provide the flow resistance necessary to ensure filling of all rows on pump start-up.

Mounting for Drainback Collector Modules

Figure 13. Mounting for Drainback Collector Modules


It is often impossible to configure parallel arrays because of the presence of rooftop equipment, roof penetrations, or other building-imposed constraints. Although the list is not complete, the following requirements should be considered when developing the array configuration:

  • Strive for a self-balancing configuration.

  • For drainback, design rows, subarrays, and arrays to be individually and collectively drainable.

  • Always locate collectors or rows with high flow resistance at the outlet to improve flow balance and ensure the drainback system fills.

  • Minimize flow and heat transfer losses.

Direct-Return Array Piping

Figure 14. Direct-Return Array Piping


In general, it is easier to configure complex array designs for nonfreezing fluid systems. Newton and Gilman (1983) provide some typical examples. However, with careful attention to these criteria, it is also possible to design successful large drainback arrays.

 Air Systems.
 Air distribution within the collector array is the most critical feature of an air system for effective operation. Proper airflow must take into account the overall pressure drop to allow efficient fan motor sizing. Balancing, automatic, backdraft, and fire dampers are usually needed. Air leaks (both into and out of the ducts and from component to component) must be minimized.

For example, some air collector systems contain a water coil for preheating water. Despite the inclusion of automatic and backdraft dampers, leakage within the system can freeze coils. One possible solution is to position the coil near the warm end of the storage bin. Another is to circulate an antifreeze solution in the coil. Whatever the solution, the designer must remember that even the lowest-leakage dampers will leak if improperly installed or adjusted.

As with liquid systems, the main supply and return ducts should be connected in a reverse-return configuration, with balancing dampers on each supply branch to the collector modules. If reverse return is not feasible, the main ducts should include balancing dampers at strategic locations. Here too, having fewer branch ducts reduces balancing needs and costs.

Unlike liquid systems, air collectors can be built on site. Although material and cost savings can be substantial with site-built collectors, extreme care is necessary to ensure long life, low leakage, and proper air distribution. Quality control in the field can be a problem, so well-trained designers and installers are critical to the success of these systems.

 Performance.
 The effect of array and air distribution system designs on the overall system performance must be considered. Beckman et al. (1977) give standard procedures for estimating the impact of series connection and duct thermal losses. The effect on fan operation and fan power is more difficult to determine. For unique system designs and more detailed performance estimates, including fan power, an hourly simulation such as TRNSYS (Klein et al. 2010) can be used.

 Shading

When large collector arrays are mounted on flat roofs or level ground, multiple rows of collectors are usually installed in a sawtooth fashion. These multiple rows should be spaced so that they do not shade each other at low sun angles. However, it is usually not desirable to avoid mutual shading altogether. Additional rows can sometimes be added to a roof or other constrained area; this increases the solar fraction but sacrifices efficiency. Kutscher et al. (1982) presents a method of estimating the energy delivered annually when there is some row-to-row shading in the array. The most common practice is to base row spacing on the lowest sun angle during the most important time of the year. For example, water and pool heating systems that operate mostly in the summer can use the higher sun angles of summer or spring and fall. Space-heating systems may want to maximize exposure in the winter, so they should use the lowest sun angle at the winter solstice. A system that operates year round may use the spring equinox sun angle as a reasonable compromise to allow more rows.

 Thermal Collector Performance

Under steady-state flow conditions, the useful heat delivered by a solar collector is equal to the energy absorbed in the heat transfer fluid minus the direct and indirect heat losses from the surface to the surroundings. This principle can be stated in the following relationship:

(3)

where

qu

=

useful energy delivered by collector, Btu/h

Ac

=

total aperture collector area, ft2

It

=

irradiance, total (direct plus diffuse) solar energy incident on upper surface of sloping collector structure, Btu/h · ft2

τ

=

transmittance (fraction of incoming solar radiation that reaches absorbing surface), dimensionless

α

=

absorptance (fraction of solar energy reaching surface that is absorbed), dimensionless

UL

=

overall heat loss coefficient, Btu/h · ft2 · °F

t̅p

=

average temperature of absorbing surface of absorber plate, °F

ta

=

atmospheric temperature, °F

Except for average plate temperature t̅p, these terms can be readily determined. For convenience, Equation (3) can be modified by substituting inlet fluid temperature for the average plate temperature, if a suitable correction factor is included. The resulting equation is

(4)

where

FR

=

correction factor, or collector heat removal efficiency factor; <1.0

ti

=

temperature of fluid entering collector, °F

The heat removal factor FR can be considered the ratio of the heat actually delivered to that delivered if the collector plate were at a uniform temperature equal to that of the entering fluid. An FR of 1.0 is theoretically possible if (1) the fluid is circulated at such a high rate that its temperature rise is negligible, and (2) the heat transfer coefficient and fin efficiency are so high that the temperature difference between the absorber surface and the fluid is negligible.

In Equation (4), the temperature ti of the inlet fluid depends on the characteristics of the complete solar heating system and the building’s heat demand. However, FR is affected only by the solar collector characteristics, fluid type, and fluid flow rate through the collector.

Solar air heaters remove substantially less heat than liquid collectors. However, their lower collector inlet temperature makes their system efficiency comparable to that of liquid systems for space-heating applications.

Equation (4) may be rewritten in terms of the instantaneous efficiency of total solar radiation collection by dividing both sides of the equation by It Ac. The result is

(5)

where η = collector efficiency, dimensionless.

Equation (5) plots as a straight line on a graph of efficiency versus the heat loss parameter (ti – ta)/It. Plots of Equation (5) for various liquid collectors are shown in Figure 15. The intercept (intersection of the line with the vertical efficiency axis) equals FRτα. The slope of the line (i.e., any efficiency difference divided by the corresponding horizontal scale difference) equals –FRUL. If experimental data on collector heat delivery at various temperatures and solar conditions are plotted, with efficiency as the vertical axis and (ti – ta)/It as the horizontal axis, the best straight line through the data points correlates collector performance with solar and temperature conditions. The intersection of the line with the vertical axis is where the temperature of the fluid entering the collector equals the ambient temperature, and collector efficiency is at its maximum. At the intersection of the line with the horizontal axis, collection efficiency is zero. This condition corresponds to such a low radiation level, or to such a high temperature of the fluid into the collector, that heat losses equal solar absorption, and the collector delivers no useful heat. This condition, normally called stagnation, usually occurs when no coolant flows to a collector. Solving Equation (5) for ti under the hottest conditions yields the stagnation temperature for the collectors at that site.

Solar Collector Type Efficiencies

Figure 15. Solar Collector Type Efficiencies


Equation (5) includes all important design and operational factors affecting steady-state performance except collector flow rate and solar incidence angle. Flow rate indirectly affects performance through the average plate temperature. If the heat removal rate is reduced, the average plate temperature increases, and more heat is lost. If the flow is increased, collector plate temperature and heat loss decrease.

 Solar Incidence Angle.
 These relationships assume that the sun is perpendicular to the plane of the collector, which rarely occurs. For glass cover plates, specular reflection of radiation occurs, thereby reducing the τα product. The incident angle modifier Kτα, defined as the ratio of τα at some incidence angle θ to τα at normal radiation (τα)n, is described by the following simple expression for specular reflection:

(6)

For a single glass cover, bo is approximately –0.10. Many flat-plate collectors, particularly evacuated tubes, have some limited focusing capability. The incident angle modifiers for these collectors are not modeled well by Equation (6), which is a linear function of (1/cos θ) – 1.

 Cellular Flow Rate.
 Equation (5) is not convenient for air collectors when it is desirable to present data based on collector outlet temperature tout rather than inlet temperature, which is the commonly measured variable for liquid systems. The relationship between the heat removal factors for these two cases is

(7a)

(7b)

where ṁcp is mass flow times specific heat of air, FRUL and FRτα apply to ti – ta in Equation (5), and (FRUL)′ and (FRτα)′ apply to tout – ta.

 Testing Methods

ASHRAE Standard 93 gives information on testing solar energy collectors using single-phase fluids and no significant internal storage. The data can be used to predict performance in any location and under any conditions where load, weather, and insolation are known.

The standard presents efficiency in a modified form of Equation (5). It specifies that the efficiency be reported in terms of gross collector area Ag rather than aperture collector area Ac. The reported efficiency is lower than efficiency based on net area, but the total energy collected does not change by this simplification. Therefore, gross collector area must be used when analyzing performance of collectors based on experiments that determine FRτα and FRUL according to ASHRAE Standard 93.

Standard 93 suggests that testing be done at 14.7 lbm/h per square foot of gross collector area for liquid systems, and that the test fluid be water. Although it is acceptable to use lower flow rates or a heat transfer fluid other than water, the designer must adjust the FR for a different heat removal rate based on the product ṁcp of mass flow and specific heat. The following approximate approach may be used to estimate small changes in ṁc p:

(8)

Air collectors are tested at a flow rate of 2 cfm per square foot, and the same relationship applies for adjusting to other flow rates. Annual compilations of collector test data that meet the criteria of ASHRAE Standards 93 (for glazed solar collectors) and 96 (for unglazed solar collectors) may be obtained from Solar Rating and Certification Corporation (www.solar-rating.org).

Another source for this information is the collector manufacturer. However, a manufacturer sometimes publishes efficiency data at a much higher flow rate than the recommended design value, so collector data should be obtained from an independent laboratory qualified to conduct testing prescribed by ASHRAE Standard 93.

 Collector Test Results and Initial Screening Methods

Final collector selection should be made only after energy analyses of the complete system, including realistic weather conditions and loads, have been determined. Also, a preliminary screening of collectors with various performance parameters should be conducted to identify those that best match the load. One way to accomplish this is to identify the expected range of heat loss parameter (ti – ta)/It for the load and climate on a plot of efficiency η as a function of heat loss parameter, as indicated in Figure 15.

Ambient temperature during the swimming season may vary by 18°F above or below pool temperature. The corresponding parameter values range from 0.15 Btu/h · ft2 · °F on cool overcast days (low It) to as low as –0.15 Btu/h · ft2 · °F on hot overcast days. For most swimming pool heating, unglazed collectors offer the highest performance and are the least expensive.

The heat loss parameter for service water heating can range from 0.05 to 0.35 Btu/h · ft2 · °F, depending on the climate at the site and the desired hot-water delivery temperature. Convective space heating requires an even greater collector inlet temperature than water heating, and the primary load coincides with lower ambient temperature. In many areas of the United States, space heating coincides with low radiation values, which further increases the heat loss parameter. However, many space-heating systems are accompanied by water heating, and some space-heating systems (e.g., radiant panels) are available at a lower (ti – ta)/It value.

Air conditioning with solar-activated absorption equipment is economical only when the cooling season is long and solar radiation levels are high. These devices require at least 180°F water. Thus, on an 80°F day with radiation at 300 Btu/h · ft2, the heat loss parameter is 0.3. Higher operating temperatures are desirable to prevent excessive derating of the air conditioner. Only the most efficient (low FRUL) collector is suitable. Derating may also be minimized by using convective-radiant hybrid air-conditioning systems.

Collector efficiency curves may be used as an initial screening device. However, efficiency curves illustrate only instantaneous performance of a collector. They do not include incidence angle effects (which vary throughout the year); heat exchanger effects; probabilities of occurrence of ti, ta, and It; system heat loss; or control strategies. Final selection requires determining a collector’s long-term energy output and performing cost-effectiveness studies. Estimating a particular collector’s and system’s annual performance requires appropriate analysis tools such as f-Chart (Beckman et al. 1977) or TRNSYS (Klein et al. 2010). The Solar Rating and Certification Corporation (SRCC), International Organization for Standardization (ISO), European Committee for Standardization (CEN), and other rating agencies provide day-long collector outputs under various solar and operating conditions. These ratings can greatly simplify selection of the proper collector type, including cost considerations. Table 2 shows a comparison of generic types of liquid flat-plate collectors.

 Generic Test Results

The generic types of liquid flat-plate collectors are unglazed, single-glazed painted- and selective-surface absorbers, and evacuated tubes. Table 2 shows the average output, intercept, and slope for these. The normalized day-long energy output for a clear day in category C points out the difficulties in using only the instantaneous efficiency data. Category C holds the temperature difference constant at 36°F all day, and a clear day is defined as 2000 Btu/ft2 · day, which is high for most of the United States. Note that evacuated-tube collectors do not perform very well under these circumstances. SRCC and other rating agencies publish a matrix of collector outputs for various temperature differences and solar days. Table 3 shows the SRCC matrix for each generic collector type. Further explanation of the categories is available on the SRCC website, www.solar-rating.org, or in their standards.

Table 2. Average Performance Parameters* for Generic Types of Liquid Flat-Plate Collectors

Collector Type

Vertical Intercept

Slope, Btu/h · ft2 · °F

Clear-Day Category C Output, Btu/h · ft2 · °F

Unglazed

0.807

−3.289

420

Glazed painted absorber

0.701

−1.15

927

  Selective-surface absorber

0.699

−0.814

1007

Evacuated tube

0.554

−0.443

840

* Derived from data of Solar Rating and Certification Corporation (SRCC), www.solar-rating.org (Oct. 2006).


Table 3. Thermal Performance Ratings* for Generic Types of Liquid Flat-Plate Collectors

Category*

Solar Day, Btu/ft2 · day

Clear Day 2000

Mildly Cloudy 1500

Cloudy Day 1000

Unglazed

  A

1600

1200

900

  B

1000

700

400

  C

400

200

—

  D

—

—

—

  E

—

—

—

Painted

  A

1285

971

658

  B

1128

815

533

  C

908

595

282

  D

407

157

—

  E

—

—

—

Selective surface

  A

1316

971

658

  B

1191

877

564

  C

1003

689

376

  D

595

313

63

  E

219

31

—

Evacuated tube

  A

872

655

436

  B

841

623

405

  C

810

592

374

  D

685

467

280

  E

592

374

156

*Categories

Ti – Ta, °F

Application

  A

–9

Pool heating, warm climate

  B

  9

Pool heating, cool climate

  C

  36

Water heating, warm climate

  D

  90

Water heating, cool climate

  E

  144

Air conditioning

* Derived from data of Solar Rating and Certification Corporation (SRCC), www.solar-rating.org (Oct. 2006).


The daily outputs in Table 3 show a clear advantage for each type of collector starting from the upper left corner and proceeding diagonally down and across. At low temperature differences, for categories A and B under clear and mildly cloudy conditions, unglazed collectors provide a clear advantage. The middle of the matrix is a bit less definitive, but painted and selective-surface collectors tend to perform best in the range. At the lower right corner, evacuated tubes perform best under high temperature differences and low solar inputs. Determining where a project falls in this rating matrix is very important in selecting the proper collector; the designer should be familiar with the location’s average daily solar input and the desired operating temperature. For example, selective-surface collectors might work well for a high-temperature application in Phoenix in the summer because the daytime temperature difference is low and the solar input is high, whereas evacuated tubes are a better choice in Atlanta.

1.6 THERMAL ENERGY STORAGE

Design and selection of thermal storage equipment is one of the most neglected elements of solar energy systems. In fact, the energy storage system has an enormous influence on overall system cost, performance, and reliability, and its design is highly interactive with that of other system elements (e.g., collector loop, thermal distribution system). Thus, it should be considered within the context of the total system.

Energy can be stored in liquids, solids, or phase-change materials (PCMs). Water is the most frequently used liquid storage medium, although the collector loop may use water, oils, or aqueous glycol as a collection fluid. For service water heating and most building space heating, water is normally contained in some type of tank. Air systems typically store heat in rocks or pebbles, but sometimes use the building’s structural mass. Chapter 35 of the 2019 ASHRAE Handbook—HVAC Applications and ASHRAE (1991) cover this topic in more detail.

 Air System Thermal Storage

The most common storage media for air collectors have been rocks or a regenerator matrix made from concrete masonry units (CMUs). Gravel was widely used as a storage medium because it is plentiful and relatively inexpensive; however, the inherent cost and likelihood of mold growth in humid climates put an end to its use. Other possible media include PCMs, water, and the inherent building mass.

Where large interior temperature swings are tolerable, the building’s inherent mass may be sufficient for thermal storage. Designated storage may also be eliminated where the array output seldom exceeds the concurrent demand. Loads requiring no storage are usually the most cost-effective applications of air collectors, and heated air from the collectors can be distributed directly to the space.

Water can be used as a storage medium for air collectors by using a conventional heating coil to transfer heat from the air to the water in the storage tank. Advantages of water storage include compatibility with hydronic heating systems and relative compactness (roughly one-third the volume of pebble beds).

 Liquid System Thermal Storage

For units large enough for commercial liquid systems, the following factors should be considered:

  • Pressurized versus unpressurized storage

  • External versus internal heat exchanger

  • Single versus multiple tanks

  • Steel versus nonmetallic tank(s)

  • Type of service [i.e., service hot water (SHW), building space heating (BSH), or a combination of the two]

  • Location, space, and accessibility constraints imposed by architectural limitations

  • Interconnect constraints imposed by existing mechanical systems

  • Limitations imposed by equipment availability

The following sections present examples of the more common configurations.

 Pressurized Storage.
 Defined here as storage that is open to the city water supply, pressurized storage is preferred for small service water heating systems because it is convenient and provides an economical way of meeting ASME Boiler and Pressure Vessel Code requirements with off-the-shelf equipment. Typical storage size is about 1 to 2 gal per square foot of collector area. The largest off-the-shelf water heater is 120 gal; however, no more than three or four of these should be connected in parallel. Hence, the largest storage that can be considered with off-the-shelf water heater tanks is about 360 to 480 gal, and must be compared to a single tank with the additional labor and material to connect them, plus the amount of floor space required. For larger solar hot-water and combined systems, the following concerns are important when selecting storage:
  • Higher cost per unit volume of ASME rated tanks in sizes greater than 120 gal

  • Handling difficulties because of large weight

  • Accessibility to locations suitable for storage

  • Interfacing with existing SHW and BSH systems

  • Corrosion protection for steel tanks

The choice of pressurized storage for medium-sized systems is based on the availability of suitable low-cost tanks near the site. Identifying a suitable supplier of low-cost tanks can extend the advantages of pressurized storage to larger SHW installations.

Storage pressurized at city water supply pressure is not practical for building space heating, except for small applications such as residences, apartments, and small commercial buildings.

With pressurized storage, the heat exchanger is always located on the collector side of the tank. Either the internal or external heat exchanger configuration can be used. Figure 16 illustrates the three main types of internal heat exchanger concepts: immersed coil, wraparound jacket, and tube bundle. Small tanks (less than 120 gal) are available with either of the first two heat exchangers already installed. For larger tanks, a large assortment of tube bundle heat exchangers are available that can be incorporated into the tank design by the manufacturer.

Pressurized Storage with Internal Heat Exchanger

Figure 16. Pressurized Storage with Internal Heat Exchanger


Sometimes, more than one tank is needed to meet design requirements. Additional tanks offer the following benefits:

  • Added storage volume

  • Increased heat exchanger surface

  • Reduced pressure drop in the collection loop

  • Increased stratification for larger volumes

Disadvantages compared to a single tank of the same volume include the following:

  • Higher installation costs

  • Greater space requirements

  • Higher heat losses (reduced performance)

Figure 17 illustrates the multiple-tank configuration for pressurized storage. The exchangers are connected in reverse-return fashion to minimize flow imbalance. A third tank may be added.

An external heat exchanger provides greater flexibility because the tank and heat exchanger can be selected independently of each other (Figure 18). A drawback to this method is that an additional pump, with its parasitic energy consumption, is required.

Multiple Storage Tank Arrangement with Internal Heat Exchangers

Figure 17. Multiple Storage Tank Arrangement with Internal Heat Exchangers


When selecting an external heat exchanger for a system protected by a nonfreezing liquid, consider the following factors related to start-up after at least one extremely cold night:

  • Freeze-up of the water side of the heat exchanger

  • Performance loss due to extraction of heat from storage

Pressurized Storage System with External Heat Exchanger

Figure 18. Pressurized Storage System with External Heat Exchanger


For small systems, an internal heat exchanger/tank arrangement prevents the water side of the heat exchanger from freezing. However, the energy required to maintain the water above freezing must be extracted from storage, thereby decreasing overall performance. With the external heat exchanger/tank combination, a bypass can be arranged to divert cold fluid around the heat exchanger until it has been heated to an acceptable level, such as 80°F. When the heat transfer fluid has warmed to this level, it can enter the heat exchanger without freezing or extracting heat from storage. If necessary, this arrangement can also be used with internal heat exchangers to improve performance.

 Unpressurized Storage.
 For systems greater than about 1000 ft3 (1500 gal storage volume minimum), unpressurized storage is usually more cost-effective than pressurized. In this chapter, the term unpressurized means tanks at or below the pressure expected in an unvented drainback loop.

Unpressurized storage for water and space heating implies a heat exchanger on the load side of the tank to isolate the high-pressure (potable water) loop from the low-pressure collector loop. Figure 19 illustrates unpressurized storage with an external heat exchanger. In this configuration, heat is extracted from the top of the solar storage tank, and cooled water is returned to the bottom. On the load side of the heat exchanger, water to be heated flows from the bottom of the backup storage tank, and heated water returns to the top. The heat exchanger may have a double wall to protect a potable water supply. A differential temperature controller controls the two pumps on either side of the heat exchanger. If the pumps are small, both may be controlled by the same controller without overloading it.

The external heat exchanger in Figure 19 provides good system flexibility and freedom in component selection. In some cases, system cost and parasitic power consumption may be reduced by an internal heat exchanger. Some field-fabricated heat exchangers use coiled soft copper tube. For larger systems, where custom fabrication is more feasible, a specified heat exchanger can be installed at the top of the tanks.

Unpressurized Storage System with External Heat Exchanger

Figure 19. Unpressurized Storage System with External Heat Exchanger


 Storage Tank Construction

 Steel.
 For most liquid solar energy systems, steel is the preferred material for storage tank construction. Steel tanks are relatively easy to fabricate to ASME Pressure Vessel Code requirements, readily available, and easily attached to pipes and fittings.

Steel tanks used for pressures of 30 psi and above must be ASME rated. Because water main pressure is usually above this level, open systems must use ASME code tanks. These pressure-rated storage tanks are more expensive than nonpressurized types. Costs can usually be significantly reduced if a nonpressurized tank can be used.

Steel tanks are subject to corrosion, however. Because corrosion rates increase with temperature, the designer must be particularly aware of corrosion protection methods for solar energy applications. A steel tank must be protected against (1) electrochemical corrosion, (2) oxidation (rusting), and (3) galvanic corrosion (Cole et al. 1980).

The pH of the liquid and the electric potential of the metal are the primary governing factors of electrochemical corrosion. A sacrificial anode made from a metal more reactive than steel can provide protection. Magnesium is recommended for solar applications. Because protection ends when the anode has dissolved, the anode must be inspected annually.

Oxygen can enter the tank through air dissolved in the water entering the tank or through an air vent. In pressurized storage, oxygen is continually replenished by the incoming water. Besides causing rust, oxygen catalyzes other types of corrosion. Unpressurized storage systems are less susceptible to corrosion caused by oxygen because they can be designed as unvented systems, so corrosion is limited to the small amount of oxygen contained in the initial fill water.

Coatings on the tank interior protect it from oxidation. Some of the most common coatings include the following:

  • Phenolic epoxy should be applied in four coats.

  • Baked-on epoxy is preferred over painted-on epoxy.

  • Glass lining offers more protection than the epoxies and can be used under severe water conditions.

  • Hydraulic stone provides the best protection against corrosion and increases the tank’s heat retention capabilities. Its weight may cause handling problems in some installations.

The coating should either be flexible enough to withstand extreme thermal cycling or have the same coefficient of expansion as the steel tank. In the United States, all linings used for potable water tanks should be approved by the Food and Drug Administration (FDA) for the maximum temperature expected in the tank.

Dissimilar materials in an electrolyte (water) are in electrical contact with each other and corrode by galvanic action. Copper fittings screwed into a steel tank corrode the steel, for example. Galvanic corrosion can be minimized by using dielectric bushings to connect pipes to tanks.

 Plastic.
 Fiberglass-reinforced plastic (FRP) tanks offer the advantages of low weight, high corrosion resistance, and low cost. Premium-quality resins allow operating temperatures as high as 210°F, well above the temperature imposed by flat-plate solar collectors. Before delivery of an FRP tank is accepted, inspect the tank for damage that may have occurred during shipment. The gel coat on the inside must be intact, and no glass fibers should be exposed.
 Concrete.
 Concrete vessels lined with a waterproofing membrane may also be used (in vented systems only) to contain a liquid thermal storage medium. Concrete storage tanks are inexpensive, and can be shaped to fit almost any retrofit application. Also, they have excellent resistance to the loading that occurs when they are placed below grade. Concrete tanks must have smooth corners and edges.

Concrete storage vessels have some disadvantages. Seepage often occurs unless a proper waterproofing surface is applied. Waterproofing paints are generally unsatisfactory because the concrete often cracks after settling. Other problems may occur because of poor workmanship, poor location, or poor design. Usually, tanks should stand alone and not be integrated with a building or other structure. Pay careful attention to expansion joints and seams because they are particularly difficult to seal. Sealing at pipe taps can be a problem. Penetrations should be above liquid level, if possible.

Finally, concrete tanks are heavy and may be more difficult to support in a proper location. Their weight may make insulating the tank bottom more expensive and difficult.

 Storage Tank Insulation

Heat loss from storage tanks and appurtenances is one of the major causes of poor system performance. The average R-value of storage tanks in solar applications is about half the insulation design value because of poorly insulated supports. Different standards recommend various design criteria for tank insulation. Performance requirements for unfired storage tanks are included in the service-water-heating sections of ASHRAE Standards 90.1 and 90.2. A 12 h maximum capacity loss of 1 to 2% should be feasible. The following equation can be used to calculate the insulation R-value for this requirement:

(9)

where

R

=

thermal resistivity of insulation, ft2 · h · °F/Btu

f

=

specified fraction of stored energy that can be lost in time θ

Q

=

stored energy, Btu

A

=

exposed surface area of storage unit, ft2

θ

=

given time period, h

tavg

=

average temperature in storage unit, °F

ta

=

ambient temperature surrounding storage unit during heating season, °F

The insulation factor fQ/Aθ is found from Table 4 for various tank shapes (Cole et al. 1980).

Most solar water-heating systems use large steel pressure vessels, which are usually shipped uninsulated. Materials suitable for field insulation include fiberglass, rigid foam, and flexible foam blankets. Fiberglass is easy to transport and make fire retardant, but it requires significant labor to apply and seal.

Another widely used insulation consists of rigid sheets of polyisocyanurate foam cut and taped around the tank. Material that is 3 to 4 in. thick can provide R-20 to R-30 insulation value. Rigid foam insulation is sprayed directly onto the tank from a foaming truck or in a shop. It bonds well to the tank surface (no air space between tank and insulation) and insulates better than an equivalent thickness of fiberglass. When most foams are exposed to flames, they ignite and/or produce toxic gases. When located in or adjacent to a living space, they often must be protected by a fire barrier and/or sprinkler system.

Some tank manufacturers and suppliers offer custom tank jackets of flexible foam with zipper-like connections that provide quick installation and neat appearance. Some of the fire considerations for rigid foam apply to these foam blankets.

Tank supports are a major source of heat loss. To provide suitable load-bearing capability, the supports must be in direct contact with the tank wall or attached to it. Thermal breaks must be provided between the supports and the tank (Figure 20). If insulating the tank from the support is impractical, the external surface of the supports must be insulated, and the supports must be placed on insulative material that can support the compressive load. Wood, foam glass, and closed-cell foam can be used, depending on the compressive load.

 Stratification and Short Circuiting

Because hot water rises and cold water sinks in a vessel, the pipe to the collector inlet should always be connected to the bottom of the tank. The collector then operates at its best efficiency because it is always at the lowest possible temperature. The return from the collector should always run near the bottom of the tank to encourage stratification and avoid introducing cooler fluid to the top of the tank after a draw occurs. Techniques such as using diffusers and lower flow rates have been developed to reduce destratification of flow returning from the collector. Generally, the better the tank stratification, the better the solar system performs overall. Similarly, the load should be extracted from the top of the tank, and cold makeup water should be introduced at the bottom. Because of increased static pressure, vertical storage tanks enhance stratification better than horizontal tanks.

Table 4. Insulation Factor fQ/Aθ for Cylindrical Water Tanks

 

Horizontal Tank Insulation Factor, Btu/h · ft2

Size, gal

250

3.63

3.46

3.05

2.77

500

4.57

4.36

4.84

3.49

750

5.24

4.99

4.40

3.99

1000

5.76

5.49

4.84

4.39

1500

6.60

6.28

5.54

5.03

2000

7.26

6.92

6.10

5.53

3000

8.31

7.92

6.98

6.33

4000

9.15

8.71

7.68

6.97

5000

9.86

9.39

8.28

7.51

 

Vertical Tank Insulation Factor, Btu/h · ft2

Size, gal

80

2.10

1.88

2.15

1.97

120

2.39

2.15

2.46

2.26

250

3.07

2.74

2.46

2.88

500

3.87

3.46

3.96

3.63

750

4.43

3.96

4.53

4.16

1000

4.87

4.36

4.99

4.57

1500

5.58

4.99

5.71

5.24

2000

6.13

5.49

6.28

5.76

3000

7.03

6.28

7.19

6.60

4000

7.73

6.92

7.92

7.26

5000

8.33

7.45

8.53

7.82


If a system has a rapid tank turnover or if the buffer tank of the system is closely matched to the load, thermal stratification does not offer any advantages. However, in most solar energy systems, thermal stratification increases performance because temperature differences are relatively small. Thus, any enhancement of temperature differentials improves heat transfer efficiency.

Typical Tank Support Detail

Figure 20. Typical Tank Support Detail


Thermal stratification can be enhanced by the following:

  • Using a tall vertical tank

  • Situating the inlet and outlet piping of a horizontal tank to minimize vertical fluid mixing

  • Sizing the inlets and outlets such that exhaust flow velocity is less than 2 fps

  • Using flow diffusers (Figure 21)

  • Plumbing multiple tanks in series

Multiple tanks generally yield the greatest temperature difference between cold water inlet and hot water outlet. With the piping/tank configuration shown in Figure 17, the difference can approach 30°F. In addition to the cost of the second tank, the cost of extra footings, insulation, and sensors must be considered. However, multiple tanks may save labor at the site because of their small diameter and shorter length. Smaller tanks require less demolition to install in retrofit (e.g., access through doorways, hallways, and windows).

Tank Plumbing Arrangements to Minimize Short Circuiting and Mixing (Adapted from Kreider 1982)

Figure 21. Tank Plumbing Arrangements to Minimize Short Circuiting and Mixing

(Adapted from Kreider 1982)


For additional information on stratification and thermal storage, see Chapter 51.

 Storage Sizing

The following specific site factors are related to system performance or cost.

 Solar Fraction.
 Most solar energy systems are designed to produce anywhere from 50 to 90% of the energy required to satisfy the load. If a system is sized to produce less than this, there must be greater coincidence between load and available solar energy. Therefore, smaller, lower-cost storage can be used with low-solar-fraction systems without impairing system performance.
 Load Matching.
 A commercial application’s load profile may allow using less storage without incurring performance penalties. For example, a company cafeteria or a restaurant serving large luncheon crowds has its greatest hot-water usage during, and just after midday. Because the load coincides with the availability of solar radiation, less storage is required for carryover. For loads that peak during the morning, collectors can be rotated toward the southeast (in the northern hemisphere), sometimes improving output for a given array.
 Storage Cost.
 If a solar storage tank is insulated adequately, performance generally improves with increased storage volume, but the savings must justify the investment. The cost of storage can be minimized by using multiple low-cost water heaters and unpressurized storage tanks made from materials such as fiberglass or concrete.

The performance and cost relationships between solar availability, collector design, storage design, and load are highly interactive. Furthermore, the designer should maximize the benefits from investment for at least one year, rather than for one or two months. For this reason, solar energy system performance models combined with economic analyses should optimize storage size for a specific site. Models that can determine system performance include f-Chart, SOLCOST, RETSCREEN, and TRNSYS. The f-Chart (Beckman et al. 1977) model is readily available either in worksheet form for hand calculations or as a computer program; however, it contains a built-in daily hot-water load profile of three equal draws specifically for residential applications. Experience shows that the daily hot-water profile may affect system performance by up to 20% more if the load is heavier in the evening and 20% less if the load occurs in the morning.

For daily profiles with extreme deviations from the residential profile, such as the company cafeteria example used previously, f-Chart may not provide satisfactory results. SOLCOST (DOE 1978) can accommodate user-selected daily profiles, but it is not widely available. Neither program can accommodate special days (e.g., holidays and weekends) when no service hot-water loads are present. TRNSYS (Klein et al. 2010) is a complete and extensible simulation environment for transient simulation of systems. It is time-consuming to set up and run for the first time, although the main visual interface provides some flexibility. From there on, various design parameters, such as collector area and storage size, can be easily evaluated for a given system configuration.

Many hydronic solar energy systems are used with a series-coupled heat pump or an absorption air-conditioning system. In the case of a heat pump, lower storage temperatures, which create higher collector efficiencies, are desirable. In this case, the collector size may be greater than recommended for conventional SHW or hydronic building space heating (BSH) systems. In contrast, absorption air conditioners require much higher temperatures (>175°F) than BSH or hydronic BSH systems to activate the generator (Balaras et al. 2006). Therefore, the storage-to-collector ratio can be much less than recommended for BSH. For absorption air conditioning, thermal energy storage may act as a buffer between the collector and generator, which prevents cycling caused by frequent changes in insolation level.

 Seasonal Storage.
 Installations with large solar collector areas and heat storage capacity could cover 50 to 80% of the total heat demand, or even 100% of the load when coupled with seasonal thermal energy storage (Balaras et al. 2010). A central solar heating plant with seasonal storage (CSHPSS) has three main components (Figure 22): solar collector array, seasonal storage tank, and piping network (Argiriou 1997). Heat produced by the collectors throughout the year is stored in the storage tank. This heat is then used to provide domestic hot water and space heating to the buildings, when required. A CSHPSS aims for high solar fractions (50 to 80%). The heat is distributed through a hydraulic pipe network. Although solar radiation has a low power density, which requires a large collector area with small heat losses, the output from a stratified storage has a high power density. CSHPSS is easily combined with existing district heating installations and is three to four times more cost effective compared to common small solar systems.

Schematic of CSHPSS

Figure 22. Schematic of CSHPSS


CSHPSS is more suitable for heating loads greater than 1700 million Btu/h per year; lower loads have high relative storage costs and large relative storage heat losses. The area to be covered should have a relatively high heat density for district heating to be economical. Low-temperature space heating is preferable for operation at low temperatures, especially of return water in the distribution system. On average, 2.15 to 3.23 ft2 collector area per unit heated floor area and 70.6 ft3 of storage (water equivalents) per unit collector area are needed to cover 50 to 80% of the total heating load in new buildings.

1.7 HEAT EXCHANGERS

 Requirements

The heat exchanger transfers heat from one fluid to another. In closed solar energy systems, it also isolates circuits operating at different pressures and separates fluids that must not be mixed. Heat exchangers are used in solar applications to separate the heat transfer fluid in the collector loop from the domestic water supply in the storage tank (pressurized storage) or the domestic water supply from the storage (unpressurized storage). Heat exchangers for solar applications may be placed either inside or outside the storage or drainback tank.

Selecting a heat exchanger involves the following considerations:

Performance. Heat exchangers always degrade the performance of a solar system; therefore, selecting an adequate size is important. When in doubt, select an oversized heat exchanger.

Guaranteed separation of fluids. Many code authorities require a vented, double-wall heat exchanger to ensure fluid isolation. System protection requirements may also dictate the need for guaranteed fluid separation.

Thermal expansion. The temperature in a heat exchanger may vary from below freezing to the boiling temperature of water. The design must withstand these thermal cycles without failing.

Materials. Galvanic corrosion is always a concern in liquid solar energy systems. Consequently, the piping, collectors, and other hydronic component materials must be compatible.

Space constraints. Often, space for mounting and servicing the heat exchanger is limited. Physical size and configuration must be considered during selection.

Serviceability. The water side of a heat exchanger is exposed to the scaling effects of dissolved minerals, so design must provide access for cleaning and scale removal.

Pressure loss. Energy consumed in pumping fluids reduces system performance. Pressure drop through the heat exchanger should be limited to 1 to 2 psi to minimize energy consumption.

Pressure capability. Because the heat exchanger is exposed to cold-water supply pressure, it should be rated for pressures above 75 psig.

 Internal Heat Exchanger

The internal heat exchanger can be a coil inside the tank or a jacket wrapped around the pressure vessel (see Figure 16). Several manufacturers supply tanks with either type of internal heat exchanger. However, the maximum size of pressurized tanks with internal heat exchangers is usually about 120 gal. Heat exchangers may be installed with relative ease inside nonpressurized tanks that open from the top. Figures 23 and 24 illustrate methods of achieving double-wall protection with either type of internal heat exchanger.

For installations with larger tanks or heat exchangers, a tube bundle is required. However, it is not always possible to find a heat exchanger of the desired area that will fit within the tank. Instead, a horizontal tank with the tube bundle inserted from the tank end can be used. A second option is to place a shroud around the tube bundle and to pump fluid around it (Figure 25). This approach combines the performance of an external heat exchanger with the compactness of an internal heat exchanger, but unfortunately it causes tank mixing and loss of stratification.

Cross Section of Wraparound Shell Heat Exchangers

Figure 23. Cross Section of Wraparound Shell Heat Exchangers


 External Heat Exchanger

Because an external heat exchanger is detached from the tank, it offers greater design flexibility than internal heat exchangers do and is preferred for most commercial applications. Shell-and-tube, tube-and-tube, and plate-and-frame heat exchangers are used in solar applications. Shell-and-tube heat exchangers are found in many solar designs because they are economical, easy to obtain, and constructed with suitable material; however, they normally do not have double-wall protection, which is often required for potable-water-heating applications. Several manufacturers produce tube-and-tube heat exchangers that offer high performance and the double-wall safety required by many code authorities, but they are usually limited in size. The plate-and-frame heat exchanger is more cost effective for large potable-water applications where positive separation of heat transfer fluids is required. These heat exchangers are compact and offer excellent heat transfer performance.

Double-Wall Tubing

Figure 24. Double-Wall Tubing


 Shell-and-Tube.
 Shell-and-tube heat exchangers accommodate large heat exchanger areas in a compact volume. The number of shell-side and tube-side passes (i.e., the number of times the fluid changes direction from one end of the heat exchanger to the other) is a major variable in selection. Because the exchanger must compensate for thermal expansion, flows in and out of the tube side are generally at the same end of the exchanger. Therefore, the number of tube-side passes is even. By appropriate baffling, two, four, or more tube passes may be created. However, as the number of passes increases, the path length grows, resulting in greater pressure drop of the tube-side fluid. Unfortunately, double-wall shell-and-tube heat exchangers are hard to find.

Tube Bundle Heat Exchanger with Intermediate Loop

Figure 25. Tube Bundle Heat Exchanger with Intermediate Loop


 Tube-and-Tube.
 Fluids in the tube-and-tube heat exchanger run counterflow, which gives closer approach temperatures. The exchanger is also compact and only limited by system size. Several may be piped in parallel for higher flow, or in series to provide approach temperatures as close as 15°F. Many manufacturers offer the tube-and-tube with double-wall protection.

The counterflow configuration operates at high efficiency. For two heat exchangers in series, effectiveness may reach 0.80. For single heat exchangers or multiple ones in parallel, effectiveness may reach 0.67. Tube-and-tube heat exchangers are cost effective for smaller residential systems.

 Plate-and-Frame.
 These heat exchangers are suitable for pressures up to 300 psig and temperatures to 400°F. They are economically attractive when a high-quality, heavy-duty construction material is required or if a double-wall heat exchanger is needed for leak protection. Typical applications include food industries or domestic water heating when any possibility of product contamination must be eliminated. This exchanger also gives added protection to the collector loop.

Contamination is not possible when an intermediate loop is used (Figure 26) and the integrity of the plates is maintained. A colored fluid in the intermediate loop gives a visual means of detecting a leak through changes in color. The sealing mechanism of the plate-and-frame heat exchanger prevents cross-contamination of heat transfer fluids. Plate-and-frame heat exchangers cost the same as or less than equivalent shell-and-tube heat exchangers constructed of stainless steel.

 Heat Exchanger Performance

Solar collectors perform less efficiently at high fluid inlet temperatures. Heat exchangers require a temperature difference between the two streams to transfer heat. The smaller the heat transfer surface area, the greater the temperature difference must be to transfer the same amount of heat and the higher the collector inlet temperature must be for a given tank temperature. As the solar collector is forced to operate at the progressively higher temperature associated with a smaller heat exchanger, its efficiency is reduced.

Double-Wall Protection Using Two Heat Exchangers in Series

Figure 26. Double-Wall Protection Using Two Heat Exchangers in Series


In addition to size and surface area, the heat exchanger’s configuration is important for achieving maximum performance. The performance of a heat exchanger is characterized by its effectiveness (a type of efficiency), which is defined as follows:

(10)

where

E

=

effectiveness

q

=

heat transfer rate, Btu/h

ṁcp

=

minimum mass flow rate times fluid specific heat, Btu/h · °F

thi

=

hot (collector-loop) stream inlet temperature, °F

tci

=

cold (storage) stream inlet temperature, °F

For heat exchangers located in the collector loop, minimum flow usually occurs on the collector side rather than the tank side.

The effectiveness E is the ratio between the heat actually transferred and the maximum heat that could be transferred for given flow and fluid inlet temperature conditions. E is relatively insensitive to temperature, but it is a strong function of heat exchanger design.

A designer must decide what heat exchanger effectiveness is required for the specific application. A method that incorporates heat exchanger performance into a collector efficiency equation [Equation (5)] uses storage tank temperature ts as the collector inlet temperature with an adjusted heat removal factor FR. Equation (11) relates FR and heat exchanger effectiveness:

(11)

The heat exchanger effectiveness must be converted into heat transfer surface area. Franta (1981) provides details of shell-and-tube heat exchangers and heat transfer fluids.

For more information on heat exchangers, see Chapter 48.

1.8 CONTROLS

The brain of an active solar energy system is the automatic temperature control. Numerous studies and reports of operational systems show that faulty controls, usually the sensors, are often the cause of poor performance. Reliable controllers are available, and with a full understanding of each system function, proper control systems can be designed. In general, control systems should be simple; additional controls are not a good solution to a problem that can be solved by better mechanical design. Key considerations for control system design include the following:

  • Collector sensor location/selection

  • Storage sensor location

  • Overtemperature sensor location

  • On/off controller characteristics

  • Selection of reliable solid-state devices, sensors, controllers, etc.

  • Control panel location in heated space

  • Connection of controller according to manufacturer’s instructions

  • Design of control system for all possible system operating modes, including heat collection, heat rejection, power outage, freeze protection, auxiliary heating, etc.

  • Selection of alarm indicators for pump failure, low and high temperatures, loss of pressure, controller failure, nighttime operation, etc.

Control categories to consider when designing automatic controls for solar energy systems are as follows:

  • Collection to storage

  • Storage to load

  • Auxiliary energy to load

  • Alarms

  • Miscellaneous (e.g., for heat rejection, freeze protection, draining, and overtemperature protection)

Types of controllers include snap switches, timers, photovoltaic (PV) modules, and differential temperature controllers. The latter is the most common, with PV popular for residential systems.

 Differential Temperature Controllers

Most controls used in solar energy systems are similar to those for HVAC systems. The major exception is the differential temperature controller (DTC), which is the basis of solar energy system control. The DTC is a comparing controller with at least two temperature sensors (typically at the solar collectors and storage tank) that controls one or several devices (Figure 27). On unpressurized systems, other DTCs may control extraction of heat from the storage tank.

The DTC monitors the temperature difference, and when the temperature of the panel exceeds that of the storage by the predetermined amount (generally 8 to 20°F), the DTC switches on the actuating devices. When the temperature of the panel drops to 3 to 10°F above the storage temperature, the DTC, either directly or indirectly, stops the pump. Indirect control through a control relay may operate one or more pumps and possibly perform other control functions, such as actuation of control valves.

Basic Nonfreezing Collector Loop for Building Service Hot-Water Heating (Nonglycol Heat Transfer Fluid}

Figure 27. Basic Nonfreezing Collector Loop for Building Service Hot-Water Heating (Nonglycol Heat Transfer Fluid}


The manufacturer’s predetermined set point of the DTC may be adjustable or fixed. If the controller set point is a fixed temperature differential, the controller should correspond to the requirements of the system. An adjustable differential set point makes the controller more flexible and allows it to be adjusted to the specific system. The optimum off temperature differential should be the minimum possible; the minimum depends on whether there is a heat exchanger between the collectors and storage.

If the system requires a heat exchanger, the energy transferred between two fluids raises the differential temperature set point. The minimum, or off, temperature differential is the point at which pumping the energy costs as much as the value of the energy being pumped. For systems with heat exchangers, the off set point is generally between 5 and 10°F. If the system does not have a heat exchanger, a range of 3 to 6°F is acceptable for the off set point. Heat lost in piping and power required to operate the pump should also be considered.

The optimum differential on set point is difficult to calculate because of the changing variables and conditions. Typically, the on set point is 10 to 15°F above the off set point. The optimum on set point is a balance between optimum energy collection and avoiding short-cycling the pump. ASHRAE’s Active Solar Heating System Design Manual (1988) describes techniques for minimizing short cycling.

 Photovoltaically Powered Pumps

The ability to drive a pump in direct proportion to the available irradiance without an external electric power makes PV pumps very popular in residential applications. Brush pumps powered by dc require additional maintenance, but have proven to be as reliable as their ac counterparts. The lack of larger dc brushless motors has limited adoption of this technology in commercial solar systems. Advantages of using PV pumps include an increase in day-long energy production and the security of having hot water during power outages. The primary disadvantage is the higher first cost.

 Overtemperature Protection

Overheating may occur during periods of high insolation and low load; thus, all portions of the solar energy system require protection against overheating. Liquid expansion or excessive pressure may burst piping or storage tanks, and steam or other gases in a system may restrict liquid flow, making the system inoperable. Glycols break down and become corrosive if subjected to temperatures greater than 240°F. The system can be protected from overheating by (1) stopping circulation in the collection loop until storage temperature decreases, (2) discharging overheated water from the system and replacing it with cold makeup water, or (3) using a heat exchanger coil as a means of heat rejection to ambient air.

The following questions should be answered to determine whether overtemperature protection is necessary.

  • Is the load ever expected to be off, such that the solar input will be much higher than the load? The designer must determine possibilities based on the owner’s needs and a computer analysis of system performance.

  • Do individual components, pumps, valves, circulating fluids, piping, tanks, and liners need protection? The designer must examine all components and base the overtemperature protection set point on the component that has the lowest specified maximum operating temperature. This may be a valve or pump with a 180 to 300°F maximum operating temperature. Sometimes, this criterion may be met by selecting components that can operate at higher temperatures.

  • Is steam formation or discharging boiling water at the tap possible? If the system has no mixing valve that mixes cold water with the solar-heated water before it enters the tap, the water must be maintained below boiling temperature. Otherwise, the water will flash to steam as it exits the tap and, most likely, scald the user. Some city codes require a mixing valve to be placed in the system for safety.

Differential temperature controllers are available that sense overtemperature. Depending on the controller used, the sensor may be mounted at the bottom or the top of the storage tank. If it is mounted at the bottom, the collector-to-storage differential temperature sensor can be used to sense overtemperature. Input to a DTC mounted at the top of the tank is independent of the bottom-mounted sensor, and the sensor monitors the true high temperature.

The normal action taken when the DTC senses an overtemperature is to turn off the pump to stop heat collection. After the panels in a drainback system are drained, they attain stagnation temperatures. Although drainback is not desirable, the panels used for these systems should be designed and tested to withstand overtemperature as well as the thermal shock of start-up when relatively cool water enters the stagnation-temperature panels. The temperature difference can range from 75 to 300°F. Such a difference could warp panels made with two or more materials of different thermal expansion coefficients. If the solar panels cannot withstand the thermal shock, an interlock should be incorporated into the control logic to prevent this situation. One method uses a high-temperature sensor mounted on the collector absorber that prevents the pump from operating until the collector temperature drops below the sensor set point.

If circulation stops in a closed-loop antifreeze system that has a heat exchanger, high stagnation temperatures will occur. These temperatures could break down the glycol heat transfer fluid. To prevent damage or injury caused by excessive pressure, a pressure relief valve must be installed in the loop, and a means of rejecting heat from the collector loop must be provided. The section on Hot-Water Dump describes a common way to relieve pressure. Pressure increases because of thermal expansion of any fluid; when water-based absorber fluids are used, pressure builds from boiling.

The pressure-relief valve should be set to relieve at or below the maximum operating pressure of any component in the closed-loop system. Typical settings are around 50 psig, corresponding to a temperature of approximately 300°F. However, these settings should be checked. When the pressure-relief valve does open, it discharges expensive antifreeze solution. Glycol antifreeze solutions damage many types of roof membranes. The discharge can be piped to large containers to save the antifreeze, but this design can create dangerous conditions because of the high pressures and temperatures involved.

If a collector loop containing glycol stagnates, chemical decomposition raises the liquid’s fusion point, and freezing becomes possible. An alternative method continues fluid circulation but diverts flow from storage to a heat exchanger that dumps heat to the ambient air or other sink (Figure 28). This wastes energy, but protects the system. A sensor on the solar collector absorber plate that turns on the heat rejection equipment can provide control. The temperature sensor set point is usually 200 to 250°F and depends on the system components. When the sensor reaches the high-temperature set point, it turns on pumps, fans, alarms, or whatever is necessary to reject the heat and warn of the overtemperature. The dump continues to operate until the overtemperature control in the collector loop DTC senses an acceptable drop in tank temperature and is reset to its normal state.

 Hot- Water Dump

If water temperatures above 200°F are allowed, the standard temperature-pressure (210°F, 150 psig) safety relief valve may operate occasionally. If these temperatures are reached, the valve opens, and some of the hot water vents out. However, these valves are designed for safety purposes, and after a few openings, they leak hot water. Thus, they should not be relied on as the only control device. An aquastat that controls a solenoid, pneumatic, or electrically actuated valve should be used instead.

Heat Rejection from Nonfreezing System Using Liquid-to-Air Heat Exchanger

Figure 28. Heat Rejection from Nonfreezing System Using Liquid-to-Air Heat Exchanger


 Heat Exchanger Freeze Protection

When selecting an external heat exchanger for a system protected by a nonfreezing fluid and started after an overnight (or longer) exposure to extreme cold, consider the following factors:

  • Freeze-up of the water side of the heat exchanger

  • Performance loss due to extraction of heat from storage

In small systems, an internal heat exchanger/tank can be placed on the water side of the heat exchanger to prevent freezing. However, the energy required to keep the water above freezing must be extracted from storage, which decreases overall performance. With the external heat exchanger/tank combination, a bypass can be installed (Figure 29). The controller positions the valve to bypass the heat exchanger until the fluid in the collector loop attains a reasonable level (e.g., 80°F). When the heat transfer fluid has warmed to this level, it can enter the heat exchanger without freezing or extracting heat from storage. The arrangement in Figure 29 can also be used with an internal heat exchanger, if necessary, to improve performance.

2. PHOTOVOLTAIC SYSTEMS

Photovoltaic (PV) devices, or cells, convert light directly into electricity. These cells are connected in series and parallel strings and packaged into modules to produce a specific voltage and current when illuminated. PV modules can also be connected in series or in parallel into arrays to produce larger voltages or currents. PV systems rely on sunlight, have few or no moving parts, are modular to match power requirements on any scale, are reliable and long-lived, and are easily produced. Photovoltaic systems can be used independently or in conjunction with other electrical power sources. The panels generally convert 10 to 20% of the incident solar radiation, although the exact percentage varies depending on cell type.

Nonfreezing System with Heat Exchanger Bypass

Figure 29. Nonfreezing System with Heat Exchanger Bypass


Most early PV installations were stand-alone systems (i.e., located at sites where utility power was unavailable); these applications include communications, remote power, remote monitoring, lighting, water pumping, battery charging, and cathodic protection. These systems could include a battery bank to provide power during nighttime hours. Excess power had to be generated during the day to keep the battery bank charged through a charge controller.

More recently, utility-interconnected systems predominate. These systems use an inverter to produce the ac waveform to match that of the utility. If excess power is produced during the day, it is fed back to the utility. Typically, power needed at night is drawn from the utility. If utility power is lost, these systems automatically shut down to prevent backfeeding power into the lines, to protect utility personnel.

Some hybrid systems are utility interactive but also operate in stand-alone mode. If utility power is lost, they automatically isolate critical circuits from the utility service, and power only those circuits. They have a smaller battery bank, sized to handle just the critical loads. These systems normally keep the battery bank fully charged to use at night as back-up if utility power fails.

There are also combined solar thermal and photovoltaic systems. Typically, the primary objective of these systems is to generate electricity, but because they get warm, they also take advantage of the heat collected. These systems can be either air or water based, and can be combined with booster thermal panels that raise the temperature of the heat transfer media to levels that may be more useful. One benefit of these systems is the reduced operating temperature of the PV panels, which may increase panel efficiency if the energy output (efficiency) of the panels is temperature sensitive. Space is also saved, because the combined thermal and PV systems use less surface than two separate systems.

 

 Fundamentals of Photovoltaics

 Photovoltaic Effect.
 When a photon enters a PV material, the photon can be reflected, absorbed, or transmitted through. If the photon is absorbed, an electron, with its additional energy, leaves its atom. It may also jump across an established layer of junctions (within the structure of the PV cell) laid down during the manufacturing process. With many electrons jumping the junction layer, an electric charge is established between the front and back of the PV cell. Conductors placed on the front and back of the cell provide a path through which the electrons that have built up can create a current through a load from one side of the cell to the other. Without a connection to provide an electron flow, electrons build up on one side of the junction layer until their like-charge field is large enough to repel further electrons from jumping the junctions, and the number that jump over is equaled by the number that jump back and recombine with the originating atoms. This charge field represents the open-circuit voltage of the cell.
 Cell Design.
 A PV cell consists of the active PV material, metal grids, antireflection coatings, and supporting material. The complete cell is optimized to maximize both the amount of light entering the cell and the power out of the cell. The photovoltaic material can be one of a number of compounds. Metal grids enhance current collection from the front and back of the solar cell. Grid design varies among manufacturers. The antireflective coating is applied to the top of the cell to maximize the light going into the cell; typically, this coating is a single layer optimized for sunlight. As a result, PV cells range in color from black to blue. In some, the top of the cell is covered with a semitransparent conductor that functions as both the current collector and the antireflection coating. A completed PV cell is a two-terminal device with positive and negative leads, and its output is direct current.
 Current-Voltage Curves.
 The current from a PV module depends on the external voltage applied and the amount of light on the module. When the module is short-circuited, current is at maximum (short-circuit current Isc), and voltage across the module is zero. When the PV module circuit is open, with the leads not making a circuit, voltage is at a maximum (open-circuit voltage Voc), and current is zero. In either case, at open or short circuit, the power (current times voltage) is zero. Between open and short circuit, the power output is greater than zero. A current-voltage curve (Figure 30) represents the range of combinations of current and voltage.

Power versus voltage can be plotted on the same graph. There exists an operating point Pmax, Imax, Vmax at which output power is maximized. Given Pmax, an additional parameter, fill factor FF, can be calculated such that

(12)

Representative Current-Voltage and Power-Voltage Curves for Typical Photovoltaic Cell

Figure 30. Representative Current-Voltage and Power-Voltage Curves for Typical Photovoltaic Cell


By illuminating and loading a PV module so that the voltage equals the PV cell’s Vmax, output power is maximized. The module can be loaded using resistive loads, electronic loads, or batteries. The typical parameters of a single-crystal solar cell are current density Jsc = 206 mA/in2, Voc = 0.58 V, Vmax = 0.47 V, FF = 0.72, and Pmax = 2273 mW.

 Efficiency and Power.
 Efficiency, another measure of PV cells, is the maximum electrical power output divided by the incident light power. It is commonly reported for a PV cell temperature of 77°F and incident light at an irradiance of 92.94 W/ft2 with a spectrum of 1.5 atmospheres equivalent spectral absorption (close to that of sunlight at solar noon).

 Photovoltaic Cells and Modules

 Photovoltaic Cells.
 In general, all PV cells perform similarly. However, the choice of the PV material can have important effects on system design and performance. Both the composition of the material and its atomic structure are influential. PV materials include silicon, gallium arsenide, copper indium diselenide, cadmium telluride, indium phosphide, and many others. The atomic structure of a PV cell can be single-crystal, polycrystalline, or amorphous (i.e., having no crystalline structure). The most commonly produced PV modules are made of crystalline silicon, either single-crystal or polycrystalline. The industry distinguishes between cells made with junctions embedded in the crystals, and “thin film,” made by laminating layers to produce the junctions.

Because of quantum effects, electrons designated to leave their atoms in a PV cell only absorb photon energy of a certain band of wavelengths; the other light energy is not absorbed. Multijunction cells (thin-film cells with two or more layers of junctions laid on top of one another) can have higher efficiency because each junction layer can be designed to respond to different wavelengths of incoming radiation.

 Module Construction.
 A module is a collection of PV cells that protects the cells and provides a usable operating voltage. Crystalline silicon PV cells can be fragile and susceptible to corrosion by humidity or fingerprints and can have delicate wire leads. Also, the operating voltage of a single PV cell is less than 1 V, making it unusable by itself for many applications. For example, a typical 6 × 6 in. cell operates around 0.5 V and produces approximately 8 A; if 128 cells were wired together in series in one module, then the module would produce approximately 512 W.

Depending on the manufacturer and type of PV material, modules have different appearances and performance characteristics. Also, modules may be designed for specific conditions, such as hot or marine environments.

Single-crystal and polycrystalline silicon cells are produced individually. Some amorphous silicon cells, although manufactured in large rolls, are later processed as individual cells. These cells are connected in series and parallel to produce the desired operating voltage and wattage. These strings of cells are then encapsulated with a polymer, a front glass piece, and a back material.

Cells made of amorphous silicon, cadmium telluride, or copper indium diselenide are manufactured on large rolls of material that become either the front or the back of the module. A large area of PV material is divided into smaller cells by scribing or cutting the material into electrically isolated cells. Later processing steps automatically interconnect the cells in series and parallel. Thin-film module construction can feature glass or polymer encapsulation of the cells. Polymer-encapsulated PV modules can be constructed in a lightweight, flexible (nonrigid) package for building integrated applications. Modules include a robust junction box attached to the back of the module for wiring to other modules or other electrical equipment.

 Module Reliability and Durability.
 PV modules are reliable and durable when properly made. As with any electrical equipment, the designer must verify that the product is tested or rated for the intended application. A PV module is a large-area semiconductor with no internal moving parts. Even a concentrator module has no internal moving parts, although there are external parts that keep the module aimed at the sun.

PV modules are designed for outdoor use in harsh surroundings such as marine, tropic, arctic, and desert environments. There are many international standards that test the suitability of PV modules for outdoor use in different climates. A buyer or user should check the suitability of the module for a given climate.

Modules are also tested for electrical safety. All modules have a maximum voltage rating supplied by the manufacturer or labeled on the module. This becomes important when interconnecting several modules into an array and connecting arrays to other electrical equipment. Most modules are tested for ground isolation to prevent personal injury or property damage. To meet the National Electrical Code®, modules must be listed by Underwriters Laboratories (UL) or other equivalent testing body.

 Module Performance.
 The performance output of a module is provided by the manufacturer and shown on a label on each module. The value provided is in watts per square metre, and represents the expected peak power point output of the module in watts at standard test conditions (STC). These conditions, established by international standard, are defined as 92.94 W/ft2 incident irradiation at a spectrum of 1.5 atmospheres equivalent spectral absorption, with a cell surface temperature of 77°F. Modules are typically marketed and sold by this peak watt value. Designers are cautioned that the actual performance of a module under real field conditions may be as much as 30% below the manufacturer’s listed value. Performance values independently tested at STC are available for some modules from the Florida Solar Energy Center.

Figure 31 shows that the maximum power Pmax occurs only at a single point on the curve, which is the product of the maximum power current Imax and the maximum power voltage Vmax. This point is referred to as the maximum power point (MPP).

PV cells experience daily variations in light intensity (irradiance), with the incident power from the sun varying between 0 W/ft2 (at night) and 92.9 W/ft2. Figure 32 showed that current, and therefore power, is reduced with less sunlight. The bullets on the curves represent the MPP at different insolation levels.

Module IV Curve at STC (Courtesy SunPower and Khalid Nagidi)

Figure 31. Module IV Curve at STC

(Courtesy SunPower and Khalid Nagidi)


Effect of Insolation on Module Performance

Figure 32. Effect of Insolation on Module Performance

(Courtesy SunPower and Khalid Nagidi)


Effect of Cell Temperature on Module Performance (Courtesy SunPower and Khalid Nagidi)

Figure 33. Effect of Cell Temperature on Module Performance

(Courtesy SunPower and Khalid Nagidi)


Solar PV module performance decreases with increasing temperature (Figure 33). The high cell operating temperatures have a significant effect on the operating voltage and consequently the output power. The operating current is not very sensitive to higher cell operating temperatures, so it remains relatively constant.

The California Energy Commission requires all modules to be tested under the photovoltaics for utility scale applications (PVUSA) test conditions (PTC), in addition to STC (California Public Utilities Commission 2010). PTC specifies 92.94 W/ft2 incident irradiation at a spectrum of 1.5 atmospheres equivalent spectral absorption, with an ambient temperature of 68°F. The cell is allowed to reach nominal operating cell temperature (NOCT), which may be 30 to 50°F higher than when tested at PTC. The lower the NOCT value, the lower the cell temperature, and therefore, the higher the PV module performance. PTC values give a better indication of actual operating performance; the difference in STC and PTC values indicates the specific module’s temperature dependence. The closer the PTC to STC rating, the higher the module output under more common and realistic operating conditions. The PTC-to-STC ratio is usually between 0.85 and 0.95. Thin-film modules generally have PTC values closer to STC.

All photovoltaic cells experience light-induced degradation (LID). The performance output is provided for new modules with only brief exposure. Modules with crystalline cells experience minimal LID, but thin-film cells can take up to 1000 h of exposure for the initial LID to stabilize. Most thin-film manufacturers rate the modules at the stabilized power output, allowing for an initial period of excess performance. Over 300°F, amorphous silicon modules can undergo thermal annealing, which can reverse the effects of LID (Radue and van Dyk 2010). Improving the stability of thin-film modules over exposure time is an active area of research in the PV industry.

Single- or polycrystal silicon modules generally exhibit the least power output degradation from exposure, followed by multijunction and single-junction thin-film modules; amorphous cells display the most degradation. Also, note that the performance STC test temperature is 77°F. As cells heat up, their performance declines slightly at first, but at high cell operating temperatures, output may be well below the reported STC value. When selecting equipment for PV systems, it is important to recognize the difference between published cell efficiencies of various types from laboratories and tested module efficiencies. Cell efficiencies may be developed by a lab on small test cells and use short exposure times and may not transfer to the efficiencies of manufactured modules.

Power tolerance is another indicator that tells us how close a PV module actual output would be to its rated output under STC. For example, if a 300 W module has a power tolerance of ±5%, its actual output under STC can fluctuate from 285 W to 315 W. Some PV modules have a positive only power tolerance such as “+5/–0,” which means that these modules should be able to produce at least rated power under STC, and possibly 5% more.

Most PV manufacturers provide 25-year power output warranties under STC with an average power output decrease of 0.25% per year. Almost all of them guarantee 90% power output for the first 10 years and 80% thereafter for the remaining 15 years. Few of them now provide 25-year linear power output warranties under STC.

 Related Equipment

 Batteries.
 Batteries are used in some PV systems to supply power at night or when the PV system cannot meet the demand. The selection of battery type and size depends primarily on load and availability requirements. In all cases, batteries must be located in an area without extreme temperatures and with some ventilation. Designers should be aware that all lead-acid batteries lose their effective energy capacity as the surrounding ambient temperature decreases. For optimal battery performance, battery banks should be kept between 50 and 75°F.

Battery types include lead-acid, nickel cadmium, nickel hydride, lithium, and many others. For a PV system, the main requirement is that the batteries be capable of repeated deep discharges without damage. Starting-lighting-ignition batteries (car batteries) are not designed for this and should not be used.

Deep-cycle lead-acid batteries are commonly used. These batteries can be flooded or valve-regulated (sealed) batteries and are commercially available in a variety of sizes. Flooded, or wet, batteries require greater maintenance but can last longer with proper care. Valve-regulated batteries require less maintenance. For more capacity, batteries can be arranged in parallel, but using more than three strings leads to uneven performance, premature failure of some batteries, and potentially early replacement of the entire battery bank.

 Battery Charge Controllers.
 Charge controllers regulate power from the PV modules to prevent the batteries from overcharging. The controller can be a shunt or series type and can also function as a low-battery-voltage disconnect to prevent battery overdischarge. The controller is chosen for the correct capacity and desired features.

There are four steps in charging flooded cells:

  • Bulk phase: the charge controller fills the cell from the PV array to approximately 85% of its capacity.

  • Absorption phase: voltage is maintained at the bulk set point and current is regulated to maintain that voltage.

  • Float phase: once the cell is fully charged, the controller charges the cell slightly above its resting voltage.

  • Equalization: intentional overcharge of a fully charged battery, which stirs up the electrolyte and evens out the chemical state of charge in each cell to keep the battery healthy.

Normally, controllers allow battery voltage to determine the PV system’s operating voltage. However, battery voltage may not be the optimum PV operating voltage. Some stand-alone charge controllers can optimize the operating voltage of the PV modules independently of battery voltage so that the PV operates at its maximum power point. (See the Peak Power Tracking section.) On the other hand, because the maximum power point tracker also uses some of the energy produced by the PV array, this approach may not always increase the total system’s efficiency over the entire year, especially if the battery and PV arrays are carefully matched.

 Inverters.
 An inverter is used to convert direct current (dc) into alternating current (ac) electricity. The inverter’s output can be single-phase or multiphase, with a voltage of 120 V, 220 V, 440 V, etc., and a frequency of 50 or 60 Hz. Inverters are rated by total power capacity, which ranges from hundreds of watts to megawatts. Some inverters have good surge capacity for starting motors; others have limited surge capacity. The designer should specify both the type and the size of the load the inverter is intended to service.

The output waveform of the inverter, though still ac, can be square, modified square (also called modified sine wave), or sine. For some small applications, modified sine wave inverters are available. Inverters should be selected with care, because equipment that contains silicon-controlled rectifiers (SCRs) or variable-speed motors, such as some vacuum cleaners and laser printers, can be damaged by square- and modified-square-wave inverter outputs. Electric utilities supply sine wave output, and most manufacturers produce inverters with sine wave outputs that avoid unexpected equipment damage. Sine wave inverters generate a wave form very close to that provided by the utility grid. Some can supply ac power that is better regulated and even has lower total harmonic distortion (THD) than utility power. All grid-tied inverters must have anti-islanding protection built in so they can be turned off automatically if the utility grid loses power, to protect utility workers from electrical shocks.

Stand-alone inverters (string and micro types) can supply the ac waveform independently. Utility-interactive inverters synchronize the waveform frequency to another ac power supply such as the electric utility or perhaps can be matched to a portable electrical generator. String inverters can support large number of PV modules connected to a single inverter, whereas microinverters control the output of individual PV modules. Each module has its own microinverter and therefore acts as maximum power point tracker. One benefit of the microinverter is that, because each PV module is individually optimized, modules with different directions and/or shading may in some cases perform better than an array of modules connected to one inverter.

 Peak Power Tracking.
 Peak power tracking varies the operating voltage of the PV array to optimize the current for maximum power production. Typically, the PV array output wattage is sampled and the voltage is adjusted automatically many times a second. Peak power trackers can be purchased separately or specified as an option with battery-charge controllers. Off-the-shelf inverters typically have peak power tracking circuitry built in. Peak power trackers consume some of the energy generated by the PV array.
 Solar Tracking Systems.
 There are three types of solar tracking systems. The single-axis tracker follows the sun from east to west with the PV array tilted at a fixed angle. A dual-axis system tracks the sun from east to west and also adjusts the PV array’s north/south tilt angle to account for the sun’s solar elevation change. The azimuth tracker has a fixed slope and rotates about a vertical axis. Proper use of these systems can increase annual solar energy harvest by approximately 30% or more, if the site has adequate solar resources.
 Balance-of-System (BOS) Components.
 These components include the mounting structures and wiring, and are just as important as the other major PV system components. PV systems should be designed and installed with the intent of only minimal maintenance.

Photovoltaic modules can be mounted on the ground or on the roof of a building, or can be included as part of building components (e.g., facades, overhangs). The latter is usually referred to as building-integrated photovoltaics (BIPV). Norton et al. (2011) reviews recent research on inverters, concentrators, and thermal management systems for improved conversion efficiency and economic viability, along with advances in system design, installation, and operation. Numerous state-of-the-art BIPV-modules (i.e., standard PV-modules with variations in aesthetic features, support, or dimensions) and BIPV-construction elements (i.e., conventional construction elements with specific architectural features for photovoltaic integration) are already available in the market (Cerón et al. 2013).

Before mounting PV panels on a roof, consider whether the roof requires any maintenance. It may not be beneficial to install a system on a roof that will soon need replacement or maintenance, because of the additional work of removing and replacing the solar panels.

A structural engineer can design the support structures in accordance with local building codes. Wind and snow loading are a major design consideration. PV modules can last more than 25 years, so the support structure and building should be designed for at least as long as the PV system’s lifetime.

In the United States, wire sizing, insulation, and use of fuses, circuit breakers, and other protective devices are covered by the National Electrical Code® (NFPA Standard 70).

REFERENCES

ANL. 1981. Final reliability and materials design guidelines for solar domestic hot water systems. ANL/SDP-11. Argonne National Laboratory, Argonne, IL.

Argiriou, A.A. 1997. CSHPSS systems in Greece: Test of simulation software and analysis of typical systems. Solar Energy 60(3-4):159-170.

ASHRAE. 1988. Active solar heating systems design manual. In cooperation with Solar Energy Industries Association and American Consulting Engineers Council Research & Management Foundation.

ASHRAE. 1990. Guide for preparing active solar heating systems operation and maintenance manuals.

ASHRAE. 1991. Active solar heating systems installation manual.

ASHRAE. 2013. Energy standard for buildings except low-rise residential buildings. ANSI/ASHRAE/IES Standard 90.1-2013.

ASHRAE. 2007. Energy efficient design of low-rise residential buildings. ANSI/ASHRAE Standard 90.2-2007.

ASHRAE. 2010. Methods of testing to determine the thermal performance of solar collectors. ANSI/ASHRAE Standard 93-2010.

ASHRAE. 1989. Methods of testing to determine the thermal performance of unglazed flat-plate liquid-type solar collectors. ANSI/ASHRAE Standard 96-1980 (R1989).

ASME. 2015. Boiler and pressure vessel code. American Society of Mechanical Engineers, New York.

Balaras, C.A., H-M. Henning, G. Grossman, E. Podesser, and C.A. Infante Ferreira. 2006. Solar cooling: An overview of European applications and design guidelines. ASHRAE Journal 48(6):14-22.

Balaras, C.A., E. Dascalaki, P. Tsekouras, and A. Aidonis. 2010. High solar combi systems in Europe. ASHRAE Transactions 116(1):408-415. Paper OR-10-044.

Beckman, W.A., S. Klein, and J.A. Duffie. 1977. Solar heating design by the f-Chart method. Wiley-Interscience, New York.

California Public Utilities Commission. 2010. California solar initiative program handbook. www.gosolarcalifornia.ca.gov/documents/CSI_HANDBOOK.PDF.

Cerón, I., E. Caamaño-Martín, F.J. Neila. 2013. “State-of-the-art” of building integrated photovoltaic products. Renewable Energy 58:127-133.

Cole, R.L., K.J. Nield, R.R. Rohde, and R.M. Wolosewicz. 1980. Design and installation manual for thermal energy storage. ANL-79-15. Argonne National Laboratory, Argonne, IL.

DOE. 1978. SOLCOST—Solar hot water handbook; A simplified design method for sizing and costing residential and commercial solar service hot water systems, 3rd ed. DOE/CS-0042/2. U.S. Department of Energy, Washington, D.C.

EPIA. 2014. Global market outlook for photovoltaics until 2014-2018. European Photovoltaic Industry Association, Brussels, June.

ESTIF. 2014. Solar thermal markets in Europe—Trends and market statistics 2013. European Solar Thermal Industry Federation, Brussels, June.

Feldman, D., G. Barbose, R. Margolis, T. James, S. Weaver, N. Darghouth, R. Fu, C. Davidson, S. Booth, and R. Wiser. 2014. Photovoltaic system pricing trends: Historical, recent, and near-term projections. NREL/PR-6A20-62558, National Renewable Energy Laboratory, Golden, CO. www.osti.gov/scitech/biblio/1159327.

Franta, G. 1981. Solar design workbook. Solar Energy Research Institute, Golden, CO.

Kalogirou, S., Y. Tripanagnostopoulos, and M. Souliotis. 2005. Performance of solar systems employing collectors with colored absorber. Energy and Buildings 37(8):824-835.

Klein, S.A., et al. 2010. TRNSYS 17: A transient system simulation program. Solar Energy Laboratory, University of Wisconsin-Madison.

Knowles, D.S. 1981. A simple balancing technique for liquid cooled flat plate solar collector arrays. International Solar Energy Society, Phoenix, AZ.

Kreider, J. 1982. The solar heating design process—Active and passive systems. McGraw-Hill, New York.

Kutscher, C.F., R.L. Davenport, D.A. Dougherty, R.C. Gee, P.M. Masterson, and E.K. May. 1982. Design approaches for solar industrial process heat systems. SERI/TR-253-1356. Solar Energy Research Institute, Golden, CO.

Newton, A.B., and S.F. Gilman. 1983. Solar collector performance manual. ASHRAE SP32.

NFPA. 2011. National electrical code®. ANSI/NFPA Standard 70-11. National Fire Protection Association, Quincy, MA.

Norton, B., P.C. Eames, T.K. Mallick, M.J. Huang, S.J. McCormack, J.D. Mondol, and Y.G. Yohanis. 2011. Enhancing the performance of building integrated photovoltaics. Solar Energy 85(8):1629-1664.

Radue, C., and E.E. van Dyk. 2010. A comparison of degradation in three amorphous silicon PV module technologies. Solar Energy Materials and Solar Cells 94(3):617-622.

REN21. 2014. Renewables 2014 global status report. Renewable Energy Policy Network for the 21st Century, Paris, September. www.ren21.net/ren21activities/globalstatusreport.aspx.

SEIA. 2014. United States Installs 1,354 MW of Solar in Q3 2014. Solar Energy Industries Association, Washington, D.C., December. www.seia.org/news/united-states-installs-1354-mw-solar-q3-2014.

Todorovic, M.S., Pejkovic, and V. Zenovic, 2010. 3.5 MW seawater heat pump assisted multipurpose solar system’s 25 years of operation. ASHRAE Transactions 116(1): 27-241.

Weiss, W., and F. Mauthner. 2014. Solar heat worldwide. Solar Heat & Cooling Programme, International Energy Agency, Gleisdorf, Austria. www.iea-shc.org/solar-heat-worldwide.

BIBLIOGRAPHY

Architectural Energy Corporation. 1991. Maintenance and operation of stand-alone photovoltaic systems, vol. 5. Naval Facilities Engineering Command, Charleston, SC.

ASHRAE. 1994. Design guide for cool thermal storage.

ASHRAE/USGBC. 2014. Standard for the design of high-performance green buildings. ANSI/ASHRAE/USGBC/IES Standard 189.1-2014. ASHRAE and U.S. Green Building Council, Washington, D.C.

ASTM. 2015. Standard test method for photovoltaic modules in cyclic temperature and humidity environments. ASTM Standard E1171-15. ASTM International.

ASTM. 2015. Standard test method for saltwater immersion and corrosion testing of photovoltaic modules for marine environments. ASTM Standard E1597-10 (2015). American Society for Testing and Materials, West Conshohocken, PA.

Davidson, J., and F. Orner. 2008. New solar electric home: The complete guide to photovoltaics for your home, 3rd ed. Chelsea Green Publishing, VT.

Eiffert, P., and G.J. Kiss. 2000. Building-integrated photovoltaics for commercial and institutional structures: A sourcebook for architects and engineers. NREL/BK-520-25272. National Renewable Energy Laboratory, Golden, CO.

The German Energy Society. 2008. Planning and installing photovoltaic systems: A guide for installers, architects and engineers, 2nd ed. Earthscan, London.

Henning, H-M., M. Motta, and D. Mugnier, eds. 2013. Solar cooling handbook—A guide to solar assisted cooling and dehumidification processes. AMBRA|V part of Walter de Gruyter GmbH, Vienna.

ICBO. 1997. Uniform building code. International Conference of Building Officials, Whittier, CA.

IEA. Photovoltaic Power Systems Programme. International Energy Agency. www.iea-pvps.org.

IEA. Solar Heating and Cooling Programme. International Energy Agency. www.iea-shc.org.

Klein, S.A., and W.A. Beckman. 2001. Solar systems analysis, F-chart user’s manual. F-Chart Software, Madison, WI.

Klein, S.A., and W.A. Beckman. 2001. Photovoltaic systems analysis, PV F-chart user’s manual. F-Chart Software, Madison, WI.

Klise, G.T., and J.S. Stein. 2009. Models used to assess the performance of photovoltaic systems. SAND2009-8258. Sandia National Laboratories, Albuquerque, NM.

Lawrence, T., A.K. Darwich, and J.K. Means, eds. 2013. ASHRAE greenguide: Design, construction, and operation of sustainable buildings, 4th ed.

Marion, W., and S. Wilcox. 1994. Solar radiation data manual for flat-plate and concentrating collectors. NREL/TP-463-5607. National Renewable Energy Laboratory, Golden, CO.

Marion, W., and S. Wilcox. 1995. Solar radiation data manual for buildings. NREL/TP-463-7904. National Renewable Energy Laboratory, Golden, CO.

Risser, V., and H. Post, eds. 1995. Stand-alone photovoltaic systems: A handbook of recommended design practices. SAND87-7023. Photovoltaic Design Assistance Center, Sandia National Laboratories, Albuquerque, NM.

Strong, S., and W.G. Scheller. 1993. The solar electric house: Energy for the environmentally-responsive, energy-independent home, 2nd ed. Chelsea Green, White River Junction, VT.

Swift, J.M., and T. Lawrence (eds). 2010. ASHRAE greenguide: The design, construction, and operation of sustainable buildings, 3rd ed.

Wiles, J. 2003. Photovoltaic systems and the National Electrical Code—Suggested practices. Photovoltaic Design Assistance Center, Sandia National Laboratories, Albuquerque, NM.



The preparation of this chapter is assigned to TC 6.7, Solar Energy Utilization.